background image

 

10 

 

MAN-022-2-0 

LED State Descriptions 

1)

 

Power Off

: No LED arrow activity is present when the sensor is off. 

2)

 

Power  On:

  When  undocked,  the  sensor  illuminates  white  and  fades  to 

black. A magnetic field will turn the sensor on within 6 seconds, otherwise 
the arrow fades to dark and sensor turns off. 

3)

 

Charging

:  Sensor  Charging  in  the  Trigno  Base  Station  is  denoted  by 

continuous amber LED arrow illumination 

4)

 

Charge  Complete

:  Once  the  internal  sensor  battery  has  been  fully 

recharged, the LED arrow illuminates to continuous green. 

5)

 

Identification Mode

: The arrows blink white upon this software command 

so that it can be easily identified and located.   

6)

 

Startup  Scan

:  upon  power-up  the  sensor  actively  searches  for  a  host  to 

connect to (PC Base Station or BLE tablet). 

7)

 

Power Up Error

: Sensor fails self-check on power up 

8)

 

Scan (Base):

  Sensor  was previously paired and is scanning for the active 

base station. 

9)

 

Low  Power  Scan  (Base): 

Sensor  was  previously  paired  and  has  been 

scanning for the active base station for more than 5 minutes. 

10)

 

Data  Collection  (Base):

  Data  from  sensor  are  streaming  to  a  paired  PC-

connected base station. 

11)

 

Configuration  Change  (Base)

:  Sensor  acknowledges  change  in 

configuration sensor from host base station. 

12)

 

Pairing (Base)

: Sensor is performing a pair operation with the base host. 

13)

 

Pairing Success (Base)

: Sensor successfully completes a pair operation with 

the Base Station host. 

14)

 

Pairing Fail (Base)

: The pair operation did not complete successfully with 

the Base Station host.   

15)

 

Advertise (BLE):

 Sensor is broadcasting to connect with a BLE host. 

16)

 

Low Power Advertise (BLE)

: Sensor is broadcasting to connect with a BLE 

host for more than 5 minutes. 

17)

 

Data Collection (BLE)

: Sensor is sampling and streaming data to BLE host. 

18)

 

Idle (BLE): 

Sensor is waiting for a Bluetooth BLE command. 

Summary of Contents for DS-T03

Page 1: ...elsys Incorporated MAN 022 2 0 MP1313A October 2019 No part of this document may be reproduced transmitted transcribed stored in a retrieval system or translated into any language in any form by any m...

Page 2: ...Data Synchronization 8 Rechargeable Battery 8 Sealed Enclosure 8 Internal Magnetic Switch 8 Sensor LED Feedback States 9 Getting Started with the Load Cell Adapter 11 Configuring the Trigno Load Cell...

Page 3: ...cle reeducation Interpretation of the EMG and supporting signals by a qualified individual is required Rx ONLY Contraindications DO NOT USE on Patients with implanted electronic devices of any kind in...

Page 4: ...iscomfort occurs Immediately discontinue device use if a change in the device s performance is noted Contact Delsys technical support for assistance Delsys Inc guarantees the safety reliability and pe...

Page 5: ...T03 FCCID W4P SP W06 Sensor FCCID W4P SP W02 Base Station IC 8138A DST03 System 211 190332 DS T03 211 190333 SP W06 This device complies with Part 15 of the FCC Rules and Industry Canada s RSS 210 Li...

Page 6: ...t does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more...

Page 7: ...s also capable of integrating with 3rd party lab equipment through a variety of interfaces which include analog signal generation triggering scenarios and digital integration through the Trigno SDK So...

Page 8: ...conditions no RF path obstructions or interfering sources this nominal distance can be notably superseded Data Synchronization Data from each sensor and from each channel within a sensor are time sync...

Page 9: ...erns as indicated in the table below Each of these states is described in subsequent sections of this User Guide State Color Pattern Arrow Display Common States 1 Power Off Off none 2 Power On Activat...

Page 10: ...check on power up 8 Scan Base Sensor was previously paired and is scanning for the active base station 9 Low Power Scan Base Sensor was previously paired and has been scanning for the active base stat...

Page 11: ...Hz Orientation2 10 Hz 1Accelerometer and gyroscope range bandwidth and sampling rate are configured by the software 2Note that the orientation is calculated on board with a data fusion algorithm Usin...

Page 12: ...tly oriented and fully mate the plug Figure 2 Mating the Load Cell connector to the sensor connector head Ensure that the connectors are fully inserted Interfacing with the Load Cell Load cells can be...

Page 13: ...ll transducer top affixed to an isometric setup bottom The Figure above illustrates a common technique that researchers employ when using load cell type devices Each situation and use case is unique h...

Page 14: ...for proper operation While the sensors are sealed and are water resistant these should never be completely submerged in any liquid Sensor leads are delicate and should be handled gently Do not pull ki...

Page 15: ...Electrical Specifications RF Frequency Band 2400 2483 MHz ISM band Dynamic Range 1 6mV 3 25mV 6 5mV Bandwidth DC 50 Hz Accelerometer Range 2g 4g 8g 16g Accelerometer Bandwidth 50 Hz 246Hz configurable...

Page 16: ...25 6 5 16 10 4 1 0 2 7 370 111 2 4 8 16 16 2 7 370152 250 500 1000 2000 16 1 The Trigno System is designed with 16 data slots for wireless transmission Sensors can occupy up to 4 slots depending on th...

Page 17: ...4 slots depending on the sampling rate settings 2 Sampling period is the precise time elapse between samples in milliseconds The sampling rate is a rounded expression of 1 sampling period expressed a...

Page 18: ...18 MAN 022 2 0 This page intentionally left blank...

Reviews: