GAS SAFETY REQUIREMENTS 

 

 

Each  appliance  is  set  and  tested  at  the  factory  for  the  type  of  gas  supply  to  be  used. 

Identify the type of gas, either Natural Gas or LP gas and make sure that the marking on the data 
plate (rating plate) matches the gas being supplied to the side burner. The data plate is located on 
the inside right hand panel of the side burner or underside of top panel. 

 
All  gas  connections  should  be  made  by  a  qualified  technician  and  in  accordance  with 

local codes and ordinances.  The installation must conform with local codes or, in the absence of 
local  codes,  with  either  the  national  Fuel  Gas  Code,  ANSI  Z223.1/NFPA  54,  or  CAN/CGA-
B149.1, Natural Gas Installation Code or CAN/CGA-B149.2, Propane Installation Code. 

 

WARNING:  
CHECK TO ENSURE THAT THE GAS SUPPLY HOSE DOES NOT COME IN 
CONTACT WITH ANY HOT SURFACE OF THE SIDE BURNER. 
 
NEVER CONNECT THE SIDE BURNER TO AN UNREGULATED GAS 
SUPPLY. 

 
 

L.P. GAS (LIQUIFIED PETROLEUM /PROPANE)

 

If  your  side  burner  is  factory  built  for  L.P.,  the  regulator  supplied  is  set  for  11”  water 

column and is for use with L.P. gas only. The factory-recommended regulator and hose must be 
used with a 20 lb. L.P. cylinder.   

 

L.P. GAS SAFETY REQUIREMENT 

 

The  LP-gas  supply  cylinder  must  be  constructed  and  marked  in  accordance  with  the 

Specifications  for  LP-gas  Cylinders 

of  the  U.S.  Department  of  Transportation  (D.O.T.)  or  the 

National  Standards  of  Canada 

CAN/CSA-B339,  Cylinders,  Spheres  and  Tubes  for  the 

Transportation of Dangerous Goods, and Commission, 

as applicable; and  

 

1. Provided with a listed overfilling prevention device.  
2. Provided with a cylinder connection device compatible with the connection for outdoor 

cooking appliances.  

 

It must be provided with a shut-off valve terminating in gas tank valve outlet. It must include 

a  collar  to  protect  the  cylinder  valve.  The  cylinder  supply  system  must  be  arranged  for  vapor 
withdrawal.  
 

Do  not  operate  the  side  burner  indoors  or  in  any  enclosed  area.  If  the  side  burner  is  not  in 

use, the gas must be turned off at the supply cylinder. If the side burner is to be stored indoors, 
disconnect the gas supply cylinder and leave the cylinder outdoors out of reach of children and 
must not be stored in a building, garage or any other enclosed area. 

Summary of Contents for DSSB1D

Page 1: ...DELSOL SIDE BURNER INSTALLATION USE CARE MANUAL DSSB1D DSSB2 DSSB1F MODEL PN 18917B 10 15...

Page 2: ..._________________________________________________ FOR YOUR RECORDS Please record the following information and refer to them when contacting the company or an authorized service agent This information...

Page 3: ...ny other appliance A V E R T I S S E M E N T 1 Ne pas entreposer ni utiliser de l essence ni d autres vapeurs ou liquides inflammables dans le voisinage de l appareil ni de tout autre appareil 2 Une b...

Page 4: ...e and other flammable vapors and liquids 7 DO NOT obstruct the flow of combustion and ventilation air to this appliance Keep the ventilation openings of the cylinder enclosure free and clear from debr...

Page 5: ...is set for 11 water column and is for use with L P gas only The factory recommended regulator and hose must be used with a 20 lb L P cylinder L P GAS SAFETY REQUIREMENT The LP gas supply cylinder must...

Page 6: ...One side of the enclosure shall be fully open or b For an enclosure having four sides a top and a bottom 1 At least two ventilation openings at cylinder valve level shall be provided in the sidewall e...

Page 7: ...r place the cylinder onto the provided location 2 Check to ensure that the tank s gas valve on top of the cylinder is closed 3 Connect the 3 8 flare end of the hose to the grill coupling using a open...

Page 8: ...e gas side burner is factory built for Natural Gas the regulator supplied is set for 4 water column The regulator is convertible to 10 water column for plumb in system LP application Do not use with a...

Page 9: ...s used and installed with the arrow mark on the regulator pointing towards the side burner Do not use any replacement regulator other than that specified by DELSOL Use only pipe sealants that are appr...

Page 10: ...ty before each use Only the factory supplied hose and regulator must be used Use only replacement regulator and hose assemblies specified by DELSOL LEAK TEST 1 Prepare a leak testing solution of sudsy...

Page 11: ...rner to adjacent vertical combustible construction must be maintained D GAGEMENT DE TOUTE CONSTRUCTION COMBUSTIBLE Il faut maintenir une distance minimum de 12 po 30 48 cm sur les c t s et de 12 po 30...

Page 12: ...CUT OUT DIMENSIONS DELSOL SIDE BURNER...

Page 13: ...en lighting Refer to spiders and insects warning and procedure under the cleaning and maintenance page of this manual LIGHTING THE BURNERS 1 Make sure all knobs are in the OFF position 2 Turn on the g...

Page 14: ...ess steel and get baked on These can be removed by using a mild abrasive pad like Scotch Brite with a stainless steel cleaner Use the mildest cleaner and always scrub in the direction of the grain Do...

Page 15: ...EXPLODED VIEW DSSB1D...

Page 16: ...13376 UPPER BURNER 1 7 S13377 LOWER BURNER 1 8 S16000 WIRE IGNITER 10 1 9 S12677 3 8 FLARE FIP 90 DEG ELBOW COUPLING 1 10 S12618 CLOSE NPT NIPPLE 1 11 S15351 REGULATOR NG LP 1 12 S12758 PIPE MANIFOLD...

Page 17: ...EXPLODED VIEW DSSB2...

Page 18: ...LATOR NG LP 1 8 S12618 CLOSE NPT NIPPLE 1 9 S12757 PIPE MANIFOLD SIDE BURNER DOUBLE 1 10 S23165Y FRONT PANEL 1 11 S13197 DELSOL KNOB 2 12 S13215 KNOB BEZEL 2 13 S13196 DELSOL LOGO 1 14 S15150 BURNER V...

Page 19: ...EXPLODED VIEW DSSB1F...

Page 20: ...6 S13215 KNOB BEZEL 1 7 S23174 MANIFOLD MOUNTING BRACKET 1 8 S12418 3 8 X 10 FLEX TUBING W BRASS FLARE NUTS 1 9 S12758 MANIFOLD PIPE SINGLE 1 10 S15150 BURNER VALVE W FLAME THROWER 1 11 S15351 REGULA...

Page 21: ...es not apply to rust corrosion discoloration surface scratches weather and atmospheric related staining and oxidation which are normal conditions and to be expected with any outdoor products unless th...

Page 22: ...hased to properly activate your warranty This information is for our internal use only Cut Here HOW TO OBTAIN SERVICE For service please contact your DELSOL dealer or call DELSOL direct at 800 789 220...

Page 23: ...Customer Service ATTN Warranty Department 13259 East 166th Street Cerritos CA 90703 Fax no 562 802 3391 Place Postage Here Cut Here...

Reviews: