DELSOL DSSB1D Installation, Use & Care Manual Download Page 4

 

GENERAL SAFETY REQUIREMENTS: 

 

1.  The installation of this appliance must conform with local codes or, in the absence of local codes, 

either the 

National Fuel Gas Code, ANZI Z223.1/NFPA 54, or CAN/CGA-B149.1, Natural Gas 

Installation Code or CAN/CGA-B149.2

, Propane Installation Code.  

2.  This outdoor cooking gas appliance is not intended to be installed in or on recreational vehicles and 

/or boats. 

3.  This outdoor cooking gas appliance is intended for use outdoors and shall not be used in a building, 

garage or any other enclosed area.  

4.  Minimum clearance of 12 inches from the back and sides of the unit to adjacent combustible 

construction must be maintained. This outdoor cooking gas appliance shall not be located 

under overhead-unprotected combustible construction.  

5.  The utilization of an external electrical source requires that when installed, this outdoor cooking gas 

appliance must be electrically grounded in accordance with the local codes or, in the absence of local 

codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA 

C22.1. Keep any electrical supply cord, or the rotisserie motor cord and the fuel supply hose away 

from any heated surfaces.  

6.  Keep your side burner in an area clear and free from combustible materials, gasoline and other 

flammable vapors and liquids.  

7.  DO NOT obstruct the flow of combustion and ventilation air to this appliance. Keep the ventilation 

openings of the cylinder enclosure free and clear from debris.  

8.  Check all gas connections for leaks with soapy water solution and brush.  Never use an open flame.  

(Reference page 6 for leak test procedure).  

9.  Check flexible hoses for cuts and wear that may affect the safety before each use.  

10.  Never use the side burner in a windy area.  

11.  The pressure regulator and hose assembly supplied with the DELSOL Side Burner must be used. 

Replacement pressure regulators and hose assemblies must be those specified by DELSOL.  

12.  CALIFORNIA PROPOSITION 65-WARNING: The burning of gas cooking fuel generates some by-

products which are on the list of substances known by the State of California to cause cancer or 

reproductive harm. California law requires businesses to warn customers of potential exposure to 

such substances. To minimize exposure to these substances always operate this unit according to the 

use and care manual, ensuring you provide good ventilation when cooking with gas. 

 
 
 
 
 
 
 
 
 
 

In  Massachusetts:  All  gas  products  must  be  installed  using  a  “Massachusetts”  licensed  plumber  or 
gasfitt

er. A “T” handle type manual gas valve must be installed in the gas supply line to this appliance. 

This  applies  to  permanently  installed  natural  gas  and  propane  installations.    This  does  not  apply  to 
propane portable installations using a 20 pound tank. 

 

Summary of Contents for DSSB1D

Page 1: ...DELSOL SIDE BURNER INSTALLATION USE CARE MANUAL DSSB1D DSSB2 DSSB1F MODEL PN 18917B 10 15...

Page 2: ..._________________________________________________ FOR YOUR RECORDS Please record the following information and refer to them when contacting the company or an authorized service agent This information...

Page 3: ...ny other appliance A V E R T I S S E M E N T 1 Ne pas entreposer ni utiliser de l essence ni d autres vapeurs ou liquides inflammables dans le voisinage de l appareil ni de tout autre appareil 2 Une b...

Page 4: ...e and other flammable vapors and liquids 7 DO NOT obstruct the flow of combustion and ventilation air to this appliance Keep the ventilation openings of the cylinder enclosure free and clear from debr...

Page 5: ...is set for 11 water column and is for use with L P gas only The factory recommended regulator and hose must be used with a 20 lb L P cylinder L P GAS SAFETY REQUIREMENT The LP gas supply cylinder must...

Page 6: ...One side of the enclosure shall be fully open or b For an enclosure having four sides a top and a bottom 1 At least two ventilation openings at cylinder valve level shall be provided in the sidewall e...

Page 7: ...r place the cylinder onto the provided location 2 Check to ensure that the tank s gas valve on top of the cylinder is closed 3 Connect the 3 8 flare end of the hose to the grill coupling using a open...

Page 8: ...e gas side burner is factory built for Natural Gas the regulator supplied is set for 4 water column The regulator is convertible to 10 water column for plumb in system LP application Do not use with a...

Page 9: ...s used and installed with the arrow mark on the regulator pointing towards the side burner Do not use any replacement regulator other than that specified by DELSOL Use only pipe sealants that are appr...

Page 10: ...ty before each use Only the factory supplied hose and regulator must be used Use only replacement regulator and hose assemblies specified by DELSOL LEAK TEST 1 Prepare a leak testing solution of sudsy...

Page 11: ...rner to adjacent vertical combustible construction must be maintained D GAGEMENT DE TOUTE CONSTRUCTION COMBUSTIBLE Il faut maintenir une distance minimum de 12 po 30 48 cm sur les c t s et de 12 po 30...

Page 12: ...CUT OUT DIMENSIONS DELSOL SIDE BURNER...

Page 13: ...en lighting Refer to spiders and insects warning and procedure under the cleaning and maintenance page of this manual LIGHTING THE BURNERS 1 Make sure all knobs are in the OFF position 2 Turn on the g...

Page 14: ...ess steel and get baked on These can be removed by using a mild abrasive pad like Scotch Brite with a stainless steel cleaner Use the mildest cleaner and always scrub in the direction of the grain Do...

Page 15: ...EXPLODED VIEW DSSB1D...

Page 16: ...13376 UPPER BURNER 1 7 S13377 LOWER BURNER 1 8 S16000 WIRE IGNITER 10 1 9 S12677 3 8 FLARE FIP 90 DEG ELBOW COUPLING 1 10 S12618 CLOSE NPT NIPPLE 1 11 S15351 REGULATOR NG LP 1 12 S12758 PIPE MANIFOLD...

Page 17: ...EXPLODED VIEW DSSB2...

Page 18: ...LATOR NG LP 1 8 S12618 CLOSE NPT NIPPLE 1 9 S12757 PIPE MANIFOLD SIDE BURNER DOUBLE 1 10 S23165Y FRONT PANEL 1 11 S13197 DELSOL KNOB 2 12 S13215 KNOB BEZEL 2 13 S13196 DELSOL LOGO 1 14 S15150 BURNER V...

Page 19: ...EXPLODED VIEW DSSB1F...

Page 20: ...6 S13215 KNOB BEZEL 1 7 S23174 MANIFOLD MOUNTING BRACKET 1 8 S12418 3 8 X 10 FLEX TUBING W BRASS FLARE NUTS 1 9 S12758 MANIFOLD PIPE SINGLE 1 10 S15150 BURNER VALVE W FLAME THROWER 1 11 S15351 REGULA...

Page 21: ...es not apply to rust corrosion discoloration surface scratches weather and atmospheric related staining and oxidation which are normal conditions and to be expected with any outdoor products unless th...

Page 22: ...hased to properly activate your warranty This information is for our internal use only Cut Here HOW TO OBTAIN SERVICE For service please contact your DELSOL dealer or call DELSOL direct at 800 789 220...

Page 23: ...Customer Service ATTN Warranty Department 13259 East 166th Street Cerritos CA 90703 Fax no 562 802 3391 Place Postage Here Cut Here...