17
en
iF SomethinG doeS not WoRK
Check the following before calling the authorised Technical Service Centre operating in your area.
PRoBLemS
CAuSeS
SoLution
The appliance is operating in dehumi-
difying mode but the humidity does
not decrease.
The filter is clogged.
Either the temperature or the humidi-
ty in the room is too low.
The room is too large for the dehu-
midifying power of the appliance, or
there are too many sources of humidi-
ty (boiling pots, etc.).
The set humidity value is too high.
Clean the filter.
In certain conditions it is normal for
the appliance not to dehumidify.
Check the operating limits of the
appliance in the “Technical Specifi-
cations” chapter. In certain cases it is
advisable to heat the room you wish
to dehumidify.
Decrease the set humidity value.
The appliance does not operate for ap-
proximately 3 minutes after start up.
The safety device has correctly made
the appliance trip.
Wait for 3 minutes to pass.
appears on the display
appears on the display
appears on the display
The tank is missing.
The tank is full.
The tank is positioned incorrectly.
The room temperature is very low.
One of the probes is faulty or the hu-
midity in the room is too low or too
high to be detected correctly.
Put the tank back in place.
Empty the tank.
Position the tank correctly.
Increase, if possible, the room tempe-
rature.
See if the appliance starts working
again when moved into another
room with a level of humidity within
the operating limits indicated in the
“Technical Specifications” section.
If the problem persists, call the Service
Centre.
troubleshooting