background image

12

en

use

use in compliance with its intended use

This appliance is intended for domestic use only. 
Use this appliance only as described herein. 
These instructions do not intend to cover every possible con-
dition and situation that may arise.  Common sense and cau-
tion should be applied when installing, operating and storing 
any appliance.

General safeguards

•  Do not install the appliance in rooms where the air con-

tains gas, oil, sulphur or near sources of heat. 

•   Do not use the appliance on sloping surfaces. 
•   Keep the appliance at least 50 cm away from flammable 

substances (alcohol, etc.) or pressurised containers (e.g. 
aerosol cans). 

•   Do not rest objects of any kind on top of the appliance. 
•   Always  transport  the  appliance  upright  or  resting  on 

one side. 

 

Drain the condensate tank before moving the appliance. 
Wait at least 1 hour after transporting the appliance be-
fore starting it

•   R 134a is a refrigerant gas that complies with EC envi-

ronmental regulations, nevertheless avoid perforating 
the refrigerant circuit of the appliance. 

 

At the end of its service life, the air conditioner must be 
disposed of at a suitable collection centre.

 

ENVIRONMENTAL  INFORMATION:  This  unit  contains 
fluorinated greenhouse gases provided for by the Kyo-
to Protocol. The maintenance and disposal operations 
must be carried out by qualified personnel only (R134a, 
GWP=1300).

•   The materials used for packaging can be recycled. You 

are therefore advised to dispose of them in special diffe-
rentiated waste collection containers. 

•   Do not use the appliance outdoors. 
•   Do not obstruct the air intake or outlet.

uSe

Read these instructions carefully before using the appliance.
•   Keep these instructions carefully. 
 

If  the  appliance  is  transferred  to  other  owners,  they 
must also be provided with these instructions for use.

•   Failure to comply with these instructions may result in 

injury and damage to the appliance. 

 

The manufacturer is not liable for damage deriving from 
the failure to comply with the instructions for use.

•   Keep the list of Technical Service Centres and identify 

the Centre nearest you.

electrical connections

After having transported the appliance wait at least one hour 
before starting it up.

  Danger!   

Before  plugging  the  appliance  into  the 

mains, check the following: 
•   The  mains  power  supply  corresponds  to  the  working 

voltage indicated on the rating plate. 

•   The power socket and the electrical circuit are adequate 

for the required load. 

•   The mains socket is suitable for the plug, otherwise have 

the plug replaced by a qualified electrician. 

•   The mains socket is connected to an efficient earthing 

system.

Setting it up for use

Position the appliance in the room to be dehumidified.
 It is essential to leave a free space of at least 50 cm in front 
of and above the dehumidifier, so as not to obstruct the air 
intake and outlet. 
For efficient ventilation it is advisable to leave a space of at 
least 5-10 cm all around the appliance.

Applying the castors

If you wish to apply the castors to the appliance, proceed as 
follows:
1)   Make sure the appliance is unplugged and the tank is 

empty.

2)   Remove the rubber caps from the base of the appliance 

by pulling them out hard, using pliers if necessary (see 
figure 

1/a

).

3)   Apply the castors by inserting their pins into the holes 

(see figure 

1/b

).

Summary of Contents for Tasciugo DDS 20

Page 1: ...ve established that the ideal conditions for our health and home are achieved when relative humidity is between 40 and 60 With very low temperatures you are recommended to heat the room even minimally Thiswillincreasethedehumidifyingcapacityoftheappliance considerably This is the only way in fact to allow the condensation that forms on the windows and other cold surfaces to evaporate into the air ...

Page 2: ...easilyrea ched so that the plug can be removed when required If you wish to remove the plug from the socket act di rectly on the plug itself Never pull the power cable as it might be damaged Todisconnecttheappliancecompletelyyoumustremo ve the plug from the socket Do not attempt to repair the appliance if it breaks down Switch the appliance off remove the plug from the so cket and contact the Afte...

Page 3: ...o not obstruct the air intake or outlet Use Read these instructions carefully before using the appliance Keep these instructions carefully If the appliance is transferred to other owners they must also be provided with these instructions for use Failure to comply with these instructions may result in injury and damage to the appliance Themanufacturerisnotliablefordamagederivingfrom the failure to ...

Page 4: ...iscomplete putthetankbackincorrect ly being careful to position the handle as show in figure 3 b Continuous external draining If you require the appliance to operate for a long period of time without periodically emptying the tank we advise you to set up continuous draining as follows Open the door on the side of the appliance and screw the nozzle onto the fitting as shown in figure 4 Insert a gar...

Page 5: ...o set the percentage of humidity you wish to achieve in the room by increasing or decreasing it by 5 at a time It is also possible to set the timer using these but tons From 0 to 10 h the time is adjusted by 30 minute incre ments and from 10 to 24 h the time is adjusted by 1 hour increments Description of the Display The meanings of the codes or symbols which may appear on the display Stand by Thi...

Page 6: ...ctedanddisplayedmeasurements must be considered indicative Keyboard Lock Mode This mode is used to lock the keyboard with the aim of avoi ding unwanted tampering with the appliance To enable or disable this mode with the appliance on not in stand by pressandholddownthe and keysforatleast3seconds The appliance will emit an acoustic signal When the mode is enabled the symbol appears on the appliance...

Page 7: ...Furthermore it considerably reduces other irritating agents such as pollen and spores For long periods of downtime After unplugging the appliance from the power socket empty the tank Clean the filter and put it back in Cover the appliance with a plastic bag to protect it from dust TECHNICAL SPECIFICATIONS Power supply voltage See rating plate Absorbed power Maximum absorbed power Defrost device Ye...

Page 8: ...n cases it is advisable to heat the room you wish to dehumidify Decrease the set humidity value Theappliancedoesnotoperateforap proximately 3 minutes after start up The safety device has correctly made the appliance trip Wait for 3 minutes to pass appears on the display appears on the display appears on the display The tank is missing The tank is full The tank is positioned incorrectly The room te...