17
LIGHTING GAS BURNERS
FITTED WITH ELECTRONIC IGNITION
Figure 18
■
Check that the electricity is
switched on to allow spark igni-
tion.
■
Make sure that all controls are
turned to zero.
■
The gas flow to the burners is
controlled by taps. The switch for
the electric ignition is incorporat-
ed in the knobs.
■
You control the flow by turning
the knob indicator to line up
with the following symbols:
– Symbol
0
: tap closed (burner off)
– Symbol
: High (maximum)
– Symbol
: Low (minimum)
■
To ignite automatically, push the required knob down and turn it to maximum,
keeping the knob down until the burner lights.
■
You can control the temperature by the knob to “High” (maximum) from “Low”
(minimum).
■
To switch off, turn the knob clockwise until you hear the safety click.
■
Note that, if you are using a burner at the minimum setting, you turn the knob
clockwise past the maximum setting before reaching the off position.
■
Whenever the lighting of the burners is difficult due to peculiar conditions of
the gas features or supply, it is advised to repeat the ignition with the knob on
“minimum” position.
■
If when lighting any of the burners an abnormal flame appears, switch the
burner off and relight using the minimum setting.
■
If the flame is still not correct, turn the burner off and call our Customer Service
center for your nearest Authorized Delonghi Service Agent.
■
In the case of a mains failure light the burner with a match or lighted taper.
Summary of Contents for DEF605GW