TIPS FOR CORRECT USE

To ensure optimal results from your air conditioner, follow these 
recommendations:
•  close the windows and doors in the room to be air condi-

tioned. When installing the air conditioner semi-perma-
nently, you should leave a door slightly open (as little as 1 
cm) to guarantee proper ventilation.

•  Never use the appliance in very damp rooms (laundries for 

example).

•  Protect the room from direct exposure to the sun by par-

tially closing curtains and/or blinds to make the appliance 
much more economical to run. 

•  Never use the appliance outdoors.
•  Make sure there are no heat sources in the room.
•  make sure the air conditioner is standing on a level surface. 

do not cover the appliance

•  Never rest objects of any kind on the air conditioner.
•  Never obstruct the air intake or outlet grilles.

CLEANING

Before  cleaning  or  maintenance,  turn  the  appliance  off  by         
touching the  

C1

C2

C4

C11

C13

C19

C20

C9

C7

C5

C6

C3

C16

C14

C12

C10

C15

C17

C8

C18

 button, then unplug from the outlet.

CLEANING THE CABINET

You should clean the appliance with a slightly damp cloth then 
dry with a dry cloth.  For safety reasons, never wash the air con-
ditioner with water. 

Attention! 

Never use petrol, alcohol or solvents to clean the ap-

pliance. Never spray insecticide liquids or similar.

CLEANING THE BIO SILVER AIR FILTER

The BioSilver filter helps capture dust and pollen and helps re-
duce the growth of bacteria and mold on the filter.
If the filter is dirty, air circulation is compromised and the effi-
ciency of the appliance decreases. It is therefore good practice 
to clean the filter at regular intervals. The frequency depends 
on the duration and conditions of operation.  If the unit is used 
constantly or systematically, you are recommended to clean the 

filter once a week.
The filter is housed in the intake grille.
To clean the filter, extract as shown in fig. 11.  
Use a vacuum cleaner to remove the dust collected on the filter. 
If it is very dirty, immerse in warm water and rinse a number of 
times. The water should never be hotter than 40°C.
After  washing  the  filter,  allow  it  to  dry  completely  before             
repositioning it.

START OF SEASON CHECKS

Make sure the power cable and plug are undamaged and the 
earth system is efficient.
Follow the installation instructions precisely.

END OF SEASON OPERATIONS

To drain all water from the circuit, remove the external cap by 
unscrewing it in the anticlockwise direction (fig. 12) and allow 
the water to drain out into a basin. 
When the appliance is empty, replace the caps. 
Clean the filter and dry thoroughly before putting back.

TECHNICAL SPECIFICATIONS

Power supply voltage 

see rating label  

Max. absorbed power 
during air conditioning             “
Refrigerant                                      “
Cooling capacity 

          “

Frequency                        2402.0-2483.5 MHz
Maximum transmission power 0,0631 W

LIMIT CONDITIONS

Room temperature for air conditioning   

18° ÷ 35°C

Transport, filling, cleaning, recovery and disposal of 

refrigerant should be performed by a technical service 

centre appointed by the manufacturer only.

The appliance should be disposed of by a specialist centre 

appointed by the manufacturer only.

Attention!  

TO AVOID DAMAGE TO THE UNIT: 

NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR 
ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING 
THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the unit 
has been on its side, oil needs to return to the compressor to en-
sure proper function.  Without allowing the unit this time (6-24 
hours) the unit may function for only a short time, and then the 
compressor will break down from lack of oil. 

Summary of Contents for Pinguino PACEL110ERFWIFI

Page 1: ...nsible in the event of non compliance with these injury prevention standards The power cable must only be replaced by special ised technicians USE The instructions below will enable you to prepare you...

Page 2: ...lled by specialized person nel Wheninstallingtheairconditioner youshouldleaveadoor slightlyopen littleas 1cm toguaranteecorrectventilation and room pressure Keep the air hose as short and free of curv...

Page 3: ...y for 3 seconds Once theWi Fi icon is displayed it means that the following Wi Fi features are available SYMBOLWI FI FIXED it means that theWi Fi features are active AND the HomeWLAN has been found SL...

Page 4: ...ith two new LR03 AAA 1 5V batteries inserting them correctly see the directions inside the battery compartment fig 10 Replace the cover Please note If the remote control unit is replaced or discarded...

Page 5: ...ent wasting electricity by optimizing the operating period with weekly scheduling setting delayed start up or shut down of the appliance ECO REAL FEEL FUNCTION ECO REAL FEEL is the innovative De Longh...

Page 6: ...LD I DO This message will only be displayed when Real Feel function in dicating that the room humidity level is ex tremely low To resume operation switch the unit to any other mode otherthantheRealFee...

Page 7: ...ation If the unit is used constantly or systematically you are recommended to clean the filter once a week The filter is housed in the intake grille To clean the filter extract as shown in fig 11 Use...

Page 8: ...ve there are heat sources in the room oven hairdryer etc eliminate the heat sources the air exhaust hose is detached from the appliance fit the air exhaust hose in the housing at the back of the appli...

Reviews: