Height of outlet:
within the range indicated by the dotted line in the figure below.

When the unit is not in use, the outlet hole should be sealed with the stopper supplied.

Temporary installation: The outlet holes can be connected in a number of ways:

In any event, for maximum cooling efficiency the window should be closed as much as possible.

It is advisable :
— to keep the outlet free of any obstruction;
— to lower the blind partly, without obstructing the outlet, thereby reducing exposure to direct sunlight

and indoor/outdoor air exchange.

ELECTRICAL CONNECTIONS

— The mains supply, suitable for domestic electrical appliances, must correspond to the power

requirements of the air conditioner (power consumption value shown in Table 1).

— Check that the power supply voltage correspond to the voltage shown in rating label.
— Check that the mains socket is correctly earthed.

N.B.:

 

In the event that the plug supplied with the air-conditioner and complying with European regulations (EEC 7, VII) is not suitable

for your wall socket, make sure that it is replaced with a plug with a capacity of at least 10 A - 250 V (IMQ) that is also suitably earthed.
Remove the power cable from the storage compartment at the back of the unit and plug it into the socket.

THIS APPLIANCE IS MANUFACTURED TO COMPLY WITH THE RADIO INTERFERENCE REQUIRE-
MENTS PROVIDED BY COUNCIL DIRECTIVE EN 55014.

fixed
 hook

min.

cm 30

max.

cm 120

Summary of Contents for Pinguino PAC26Super

Page 1: ...time and effort to read this manual carefully Becoming familiar with the Pinguino is an essential step if you are to benefit fully from its exceptional qualities during both installation and actual us...

Page 2: ...is empty The PAC 26 Super sets the temperature automatically TECHNICAL DATA Tab 1 IDEAL OPERATING CONDITIONS AIR CONDITIONING FUNCTION Tab 2 ROOMTEMPERATURE 21 32 C FREQUENCY see rating label POWERSU...

Page 3: ...timer Control panel press to open Water container Castors Castor stops Water collecting tray Water container compartment door Air filter Air intake grid Warranty envelope Exhaust hose compartment Pow...

Page 4: ...OF ACCESSORIES Tab 4 PARTS SUPPLIED DESCRIPTION Exhaust hose Stopper flange Castor stop De scaling fluid Window nozzle Suction cup set 1 1 2 1 1 1 ACCESSORY CHECK Check that all parts listed in Table...

Page 5: ...the safety switch Air entering the room through door and window cracks is normally sufficient If necessary leave a door slightly ajar a gap of approx 1 cm is adequate The unit can also be used as a te...

Page 6: ...estic electrical appliances must correspond to the power requirements of the air conditioner power consumption value shown in Table 1 Check that the power supply voltage correspond to the voltage show...

Page 7: ...onditions such as temperature humidity insulation exposure of the room number of people present etc On average it will last approximately 7 to 10 hours When the container is empty the appliance automa...

Page 8: ...r conditioned are closed with the sole exception of the partially opened window necessary for temporary installation the room is well shaded from direct sunlight by drawing curtains and or partially l...

Page 9: ...onnected or there is a power failure the programmer stops the clock is then slow and must be re set The unit can be used in either programmed or non programmed mode PROGRAMMED MODE 1 Select the desire...

Page 10: ...nditioningfunc tiondependingontheroom temperature Pressthe Air conditioning key again to increase fan speed The Max speed warning light comes on Press the ventilation key againtoobtainMax speed The Ma...

Page 11: ...oner empty the water from the collecting tray through the drainage tube Never place hot or heavy objects on the appliance Clean the air filter once a week Avoid the use of extension leads If it is nec...

Page 12: ...y should be cleaned at least once a month to prevent dirt from accumulating after prolonged use 1 Switch off the appliance and disconnect the plug 2 Open the water container compartment door and remov...

Page 13: ...ns for only short periods as safety has been enabled The function OK signal lamp flashes Exhaust hose is blocked Exhaust hose is bent Condensator fan is blocked There are discrepancies in the control...

Page 14: ...m of the unit c Leave the air conditioner to operate for about half an hour d Drain away all the fluid left in the tray and rinse thoroughly The drainage tube should be open and the appliance switched...

Reviews: