SERVICING

PRECAUTIONS: during cleaning and normal maintenance operations, remember to disconnect the plug.
Under no circumstances should the appliance be washed with running water. Damage could be caused
to the electrical circuit.

AIR-FILTER CLEANING
— A clogged air filter reduces air circulation and the efficiency of the appliance. Clean the filter once a

week.

— To remove the filter, pull it up gently. Push down to replace.
— Use a vacuum cleaner to remove dust deposited on the filter. If it is very dirty, soak it in lukewarm water

and rinse thoroughly. The temperature of the water must be kept below 40

°

C. After washing, leave the

filter to dry before replacing.

CLEANING EXTERNAL HOUSING
Clean with a damp cloth and rub over with a clean dry cloth.
PRECAUTIONS: never use petrol, oil or similar solvents for cleaning. Never spray insecticides or similar
liquids. Serious damage may result to paintwork and plastic.

CLEANING COLLECTING TRAY
The collecting tray should be cleaned at least once a month to prevent dirt from accumulating after
prolonged use.

1) Switch off the appliance and disconnect the plug;
2) Open the water container compartment door and remove the container;
3) Remove the plug from the drainage tube situated at the back of the appliance and empty the water

into a bowl;

4) Once the container has been fully drained, replace the plug;
5) Remove any dirt from the surface below the container, rubbing with a cloth.

CONTROLS AT BEGINNING OF SEASON

Check that the condition of the power lead and socket.
Make sure that the appliance has been properly earthed and that the wire is not broken or loose.
Follow all installation procedures with maximum attention.

END OF SEASON OPERATIONS

1) De-scale the unit. (see pg. 31)
2) Empty the water collecting tray.
3) Let the fan run for about half an hour to dry the inside of the air-conditioner
4) Switch off the unit and disconnect the plug from the power supply.
5) Remove the exhaust hose
6) Clean the filter and dry well before replacing
7) Never cover the unit with bags when stored or not in use.
8) Do not store the unit in rooms or spaces measuring less than 8m

3

.

Summary of Contents for Pinguino PAC26Super

Page 1: ...time and effort to read this manual carefully Becoming familiar with the Pinguino is an essential step if you are to benefit fully from its exceptional qualities during both installation and actual us...

Page 2: ...is empty The PAC 26 Super sets the temperature automatically TECHNICAL DATA Tab 1 IDEAL OPERATING CONDITIONS AIR CONDITIONING FUNCTION Tab 2 ROOMTEMPERATURE 21 32 C FREQUENCY see rating label POWERSU...

Page 3: ...timer Control panel press to open Water container Castors Castor stops Water collecting tray Water container compartment door Air filter Air intake grid Warranty envelope Exhaust hose compartment Pow...

Page 4: ...OF ACCESSORIES Tab 4 PARTS SUPPLIED DESCRIPTION Exhaust hose Stopper flange Castor stop De scaling fluid Window nozzle Suction cup set 1 1 2 1 1 1 ACCESSORY CHECK Check that all parts listed in Table...

Page 5: ...the safety switch Air entering the room through door and window cracks is normally sufficient If necessary leave a door slightly ajar a gap of approx 1 cm is adequate The unit can also be used as a te...

Page 6: ...estic electrical appliances must correspond to the power requirements of the air conditioner power consumption value shown in Table 1 Check that the power supply voltage correspond to the voltage show...

Page 7: ...onditions such as temperature humidity insulation exposure of the room number of people present etc On average it will last approximately 7 to 10 hours When the container is empty the appliance automa...

Page 8: ...r conditioned are closed with the sole exception of the partially opened window necessary for temporary installation the room is well shaded from direct sunlight by drawing curtains and or partially l...

Page 9: ...onnected or there is a power failure the programmer stops the clock is then slow and must be re set The unit can be used in either programmed or non programmed mode PROGRAMMED MODE 1 Select the desire...

Page 10: ...nditioningfunc tiondependingontheroom temperature Pressthe Air conditioning key again to increase fan speed The Max speed warning light comes on Press the ventilation key againtoobtainMax speed The Ma...

Page 11: ...oner empty the water from the collecting tray through the drainage tube Never place hot or heavy objects on the appliance Clean the air filter once a week Avoid the use of extension leads If it is nec...

Page 12: ...y should be cleaned at least once a month to prevent dirt from accumulating after prolonged use 1 Switch off the appliance and disconnect the plug 2 Open the water container compartment door and remov...

Page 13: ...ns for only short periods as safety has been enabled The function OK signal lamp flashes Exhaust hose is blocked Exhaust hose is bent Condensator fan is blocked There are discrepancies in the control...

Page 14: ...m of the unit c Leave the air conditioner to operate for about half an hour d Drain away all the fluid left in the tray and rinse thoroughly The drainage tube should be open and the appliance switched...

Reviews: