background image

9

GB

Self-diagnosis

SETTING THE TIMER

The timer can be used to delay appliance start up or shutdown. This avoids wasting electricity by
not operating the appliance when it is not needed.

How to program delayed start up

Plug the appliance into an outlet  and press the 

ON/STAND-BY 

button (

A

), then select the desi-

red operating mode and other settings (temperature, fan speed, etc).

Press the 

ON/STAND-BY

button (

A

) again: The appliance switches to stand-by mode (the two

central segments are displayed).

Press the 

TIMER

button (

D

). The last timer setting or the preset value 

6.0

flashes on the display.

Use the + (

E

) or - (

F

) buttons to set the number of hours delay before the appliance comes on.

During the first ten hours, you can select half hour intervals.  For times greater than ten hours,
one hour intervals can be selected. If the + (

E

) or - (

F

) buttons are pressed for more than 2

seconds, the time runs rapidly up to a maximum of 24 hours. Press the timer button again within
a few seconds to confirm the setting. If the setting is not confirmed within a few seconds, the
display resets to Stand-by. With the timer activated, the countdown before the programmed
start up time is displayed and the light (

H

) flashes.

To cancel the timer programming, press the timer button (

D

) again.

How to program delayed shutdown

Delayed shutdown can be programmed in any operating mode (air conditioning/dehumi-
difying/fan).

Press the 

TIMER

button (

D

). The last timer setting or the preset value 

6.0

flashes on the display.

Use the + (

E

) or - (

F

) button to set the number of hours delay before the appliance goes off.

During the first ten hours, you can select half hour intervals. For times greater than ten hours,
one hour intervals can be selected. 
If the + (

E

) or - (

F

) buttons are pressed for more than 2 seconds, the time runs rapidly up to a

maximum of 24 hours.
Press the timer button again within a few seconds to confirm the setting.
When the timer is set, the light (

H

) flashes. 

At the set time, the air conditioner shuts down and remains in stand-by.
To cancel the timer programming, press the timer button (

D

) again.

SELF-DIAGNOSIS

The appliance has a self diagnosis system to identify a number of malfunctions.

LOW TEMPERATURE

(frost prevention)

PROBE FAILURE

(sensor damaged)

FULL TANK

The appliance is fitted with a frost protection device to avoid
excessive formation of ice  on internal components. The appliance
starts up again automatically when the defrosting process is com-
pleted

If this is displayed, contact your local authorized service centre.

Empty the internal tank, see page 14 "End of season operations"

IF ... IS DISPLAYED

...WHAT SHOULD YOU DO?

Summary of Contents for Pinguino PAC CT110

Page 1: ...by specialized per sonnel authorized by the manufacturer in order to protect against fire Always ensure the appliance is plugged into a grounded 3 prong outlet If you have any doubts check with a qua...

Page 2: ...d by a qualified professional only B Other set up methods Thanks to the locking pins it s possible to use the window bracket also for sliding windows Position the hole of the bracket so to allow a cor...

Page 3: ...nge 10 into the hole Fit the air exhaust hose 11 in the rele vant housing located on the rear side of the appliance fig A page 5 Fit the end of the hose 11 to the wall flange 10 as shown in fig G G Wh...

Page 4: ...Displays the temperature values set and the programmed operating time H Timer in operation indicator light I L M N Fan speed lights and AUTO lights O Fan mode light P Dehumidifying mode light Q Air c...

Page 5: ...iance automatically selects the most suitable fan speed in relation to the temperature set on the digital display and current room temperature The most suitable temperature for the room during the sum...

Page 6: ...ancel the timer programming press the timer button D again How to program delayed shutdown Delayed shutdown can be programmed in any operating mode air conditioning dehumi difying fan Press the TIMER...

Page 7: ...ice pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can rad...

Page 8: ...to set a temperature much below the outdoor temperature DEHUMIDIFYING MODE Ideal to reduce room humidity spring and autumn damp rooms rainy periods etc In dehumidifying mode the appliance selects fan...

Page 9: ...on 19 The time is displayed and the h symbol flashes Set the time when you want the appliance to switch off using the buttons from 30 minutes to 24 hours During the first ten hours you can select half...

Page 10: ...oom from direct exposure to the sun by partially closing curtains and or blinds to help the appliance run more effi ciently Tips close doors and windows close blinds or curtains Never rest objects of...

Page 11: ...ilter is housed in the intake grille To clean the filters proceed as follows 1 Remove the dust filter by extracting it upwards figure G 2 Use a vacuum cleaner to remove dust accumulations from the fil...

Page 12: ...Close the window Eliminate the heat source Connect the exhaust hose Clean or replace the filters Clean or replace the filter Bad odor in the room The filter is clogged The air conditioner does not op...

Page 13: ...recovery and dis posal of refrigerant should be performed by a technical service centre appointed by the manufacturer only The appliance should be disposed of by a specialist centre appointed by the m...

Page 14: ...to be paid by the owner of the unit This warranty shall apply only if the AIR CONDITIONER is used in accordance with the factory directions that accompany it and on an Alternating Current AC circuit...