Technical specifications

LIMIT CONDITIONS

Room temperature for 
air conditioning 

64 ÷ 95°F (18° ÷ 35°C)

TECHNICAL SPECIFICATION

Power supply voltage

see rating label 

Max. absorbed power 
during air conditioning

Refrigerant

Cooling capacity

SAFETY PLUG

The appliance is fitted with a safety plug to protect the power cable.
If power is cut off, unplug from the outlet and make sure the power cable is undamaged.
If the cable is damaged, call the service center immediately.
If power cuts off frequently and the power cable is undamaged, contact a qualified elec-
trician.

OPERATION OF THE SAFETY PLUG

If the safety device incorporated in the plug trips and cuts off the power supply, check
that the power cable and plug are not damaged.
If the power cable is undamaged, to restore operation press the "RESET" button. 
To verify correct operation of the plug, press the "TEST" button periodically and make sure
the appliance disconnects. If this is not the case, contact the service center.
To restore operation, press the "RESET" button.

Transport, filling, cleaning, recovery and dis-
posal of refrigerant should be performed by
a technical service centre appointed by the
manufacturer only.
The appliance should be disposed of by a
specialist centre appointed by the manu-
facturer only.

This appliance is equipped with a 3 prong grounded plug. The plug must be connected into
an outlet that  is properly installed and grounded in the accordance with all local codes
and ordinances. Do not modify the plug provided with the appliance. If it will not fit the
outlet, have a proper outlet installed by a qualified electrician or relocate the unit to a pro-
per outlet.
If the household electrical supply does not meet the above specifications, or if you are not
sure your home has an effective  electrical ground, have a qualified electrician or your local
electrical utility company check it and correct any problems.

NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS
SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING THE APPLIANCE
ON, 24 HOURS IS RECOMMENDED. (After the unit has been on its side,
oil needs to return to the compressor to ensure proper function.
Without allowing the unit this time (6-24 hours) The unit may function
for only a short time, and then the compressor will break down from
lack of oil). 

Summary of Contents for Pinguino PAC CT110

Page 1: ...by specialized per sonnel authorized by the manufacturer in order to protect against fire Always ensure the appliance is plugged into a grounded 3 prong outlet If you have any doubts check with a qua...

Page 2: ...d by a qualified professional only B Other set up methods Thanks to the locking pins it s possible to use the window bracket also for sliding windows Position the hole of the bracket so to allow a cor...

Page 3: ...nge 10 into the hole Fit the air exhaust hose 11 in the rele vant housing located on the rear side of the appliance fig A page 5 Fit the end of the hose 11 to the wall flange 10 as shown in fig G G Wh...

Page 4: ...Displays the temperature values set and the programmed operating time H Timer in operation indicator light I L M N Fan speed lights and AUTO lights O Fan mode light P Dehumidifying mode light Q Air c...

Page 5: ...iance automatically selects the most suitable fan speed in relation to the temperature set on the digital display and current room temperature The most suitable temperature for the room during the sum...

Page 6: ...ancel the timer programming press the timer button D again How to program delayed shutdown Delayed shutdown can be programmed in any operating mode air conditioning dehumi difying fan Press the TIMER...

Page 7: ...ice pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can rad...

Page 8: ...to set a temperature much below the outdoor temperature DEHUMIDIFYING MODE Ideal to reduce room humidity spring and autumn damp rooms rainy periods etc In dehumidifying mode the appliance selects fan...

Page 9: ...on 19 The time is displayed and the h symbol flashes Set the time when you want the appliance to switch off using the buttons from 30 minutes to 24 hours During the first ten hours you can select half...

Page 10: ...oom from direct exposure to the sun by partially closing curtains and or blinds to help the appliance run more effi ciently Tips close doors and windows close blinds or curtains Never rest objects of...

Page 11: ...ilter is housed in the intake grille To clean the filters proceed as follows 1 Remove the dust filter by extracting it upwards figure G 2 Use a vacuum cleaner to remove dust accumulations from the fil...

Page 12: ...Close the window Eliminate the heat source Connect the exhaust hose Clean or replace the filters Clean or replace the filter Bad odor in the room The filter is clogged The air conditioner does not op...

Page 13: ...recovery and dis posal of refrigerant should be performed by a technical service centre appointed by the manufacturer only The appliance should be disposed of by a specialist centre appointed by the m...

Page 14: ...to be paid by the owner of the unit This warranty shall apply only if the AIR CONDITIONER is used in accordance with the factory directions that accompany it and on an Alternating Current AC circuit...

Reviews: