background image

F 1 4

F 1 4

Use and maintenance manual 

5751008700  15-04-2004  16:20  Pagina 1

Summary of Contents for Pinguino F14

Page 1: ...F 1 4 F 1 4 Use and maintenance manual 5751008700 15 04 2004 16 20 Pagina 1...

Page 2: ...he world we are con stantly improving the quality and performance of Pinguino We are confident that you will be satisfied with your purchase and enjoy the cool comfort created by the Pinguino for many...

Page 3: ...1 2 3 4 5 6 7 9 15 16 18 19 17 20 8 10 11 12 14 Description CONTROL PANEL ACCESSORY SET 13 5751008700 15 04 2004 16 20 Pagina 3...

Page 4: ...transferred between different buildings The hot air in your room is passed through a coil cooled by refrigerant gas removing excess heat and moisture before being discharged again into the room In si...

Page 5: ...efore cleaning or maintenance opera tions always unplug the unit from the socket Do not pull on or place strain on the power cable when moving the applian ce The appliance should not be installed wher...

Page 6: ...dow or door Open the window French window or door slightly and place the window attachment as shown in figure B 18 17 18 A Setting up B C For optimum results If you have a sash window place the bracke...

Page 7: ...sions given in figure D 30 cm 30 cm MAX115 cm MIN 50 cm When the hose is not attached close the hole with the bung on the flange NOTE When the unit is installed semi permanently we recommend leaving a...

Page 8: ...then be automatically maintained by the thermostat with considerable energy savings When regulating the thermostat the air conditioning function is temporarily inter rupted and the unit continues to...

Page 9: ...ature will be exhausted from the accommodation tube on the back side of the appliance 3 1 9 6 TURN THE APPLIANCE OFF TO TURN THE UNIT OFF COMPLETELY SET THE FUNCTION SELECTOR TO THE POSI TION AND UNPL...

Page 10: ...rotect the room from direct exposure to the sun s rays by drawing the curtains and or partially lowering the blinds so as to maximise energy savings Do not rest objects on the air conditioning unit Do...

Page 11: ...ves To clean the filters 1 Remove the intake grills on either side of the appliance by rotating them outwards Fig F To remove dust deposited on the anti dust fil ter use a vacuum cleaner If very dirty...

Page 12: ...come out of place the air filter is dirty the air conditioner has a capacity not ade quate for the conditions or the ldimensions of the room close the open window remove the heat source reinsert the...

Page 13: ...city Number of fan speeds 2 Max air flow 360 m3 h Dimensions of internal unit width 452 mm height 800 mm depth 415 mm weight 33 5 kg Standard conditions ASHRAE 128 8 This appliance contains substances...

Page 14: ...g h i S p A V i a L S e i t z 4 7 3 1 1 0 0 Tr e v i s o I t a l i a t e l 3 9 0 4 2 2 4 1 3 1 f a x 3 9 0 4 2 2 4 1 3 6 4 7 w w w d e l o n g h i c o m 5751008700 06 02 5751008700 15 04 2004 16 20 P...

Page 15: ...15 ENGLISH 5751008700 15 04 2004 16 20 Pagina 15...

Reviews: