18

START OF SEASON CHECKS

Make sure the power cable and plug are undamaged and the 
earth system is efficient.
Follow the installation instructions precisely.

END OF SEASON OPERATIONS

To drain all water from the circuit, remove the external cap by 
unscrewing it in the anticlockwise (fig. 12) direction and allow 
the water to drain out into a basin. 
When the appliance is empty, replace the caps. 
Clean the filter and dry thoroughly before putting back.

TECHNICAL SPECIFICATIONS

Power supply voltage 

see rating label  

Max. absorbed power 
during air conditioning             “
Refrigerant                                      “
Cooling capacity 

          “

LIMIT CONDITIONS

Room temperature for air conditioning   

18° ÷ 35°C

Transport, filling, cleaning, recovery and disposal of 

refrigerant should be performed by a technical service 

centre appointed by the manufacturer only.

The appliance should be disposed of by a specialist centre 

appointed by the manufacturer only.

Attention!  

TO AVOID DAMAGE TO THE UNIT: 

NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR 
ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING 
THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the unit 
has been on its side, oil needs to return to the compressor to en-
sure proper function.  Without allowing the unit this time (6-24 
hours) the unit may function for only a short time, and then the 
compressor will break down from lack of oil. 

Summary of Contents for Pinguino Air-to-Air PAC EX130

Page 1: ...te This appliance is provided with an auto evapora tion feature for condensate removal during cooling and dehu midifying modes AIR CONDITIONING WITHOUT INSTALLATION CASEMENT WINDOW If you have a casem...

Page 2: ...C4 Temperature decrease key C5 Fan speed selection key MIN MED MAX AUTO C6 Air conditioner symbol C7 Dehumidify ng symbol C8 Fan symbol C9 ECO REAL FEEL status indicator C10 Swing symbol C11 Fan speed...

Page 3: ...is mode Touch repeatedly the MODE key C2 until the dehumidify ing symbol appears The appliance will automatically choose the best air flow FAN MODE When using this mode the air ex hausthose B2 doesnot...

Page 4: ...C7 C5 C6 C3 C16 C14 C10 C15 C17 C8 button and waiting few minutes before removing the plug Only in this way the appli ance will perform the standard checkings SELECTING THE OPERATING MODES To select...

Page 5: ...erprogram touchthetimerbutton D8 twice The timer symbol C15 will go off Pleasenote Oncethetimerhasbeenactivated bypressingthe timerkeyonlyonetime theremaininghourstothestartupwill be displayed ECO REA...

Page 6: ...e room Makesuretheairconditionerisstandingonalevelsurface donotcovertheappliance Never rest objects of any kind on the air conditioner Never obstruct the air intake or outlet flap CLEANING Before clea...

Page 7: ...gerant Cooling capacity LIMIT CONDITIONS Room temperature for air conditioning 18 35 C Transport filling cleaning recovery and disposal of refrigerant should be performed by a technical service centre...

Page 8: ...above there are heat sources in the room oven hairdryer etc eliminate the heat sources the air exhaust hose is detached from the appliance fit the air exhaust hose in the housing at the back of the ap...

Reviews: