Height of outlet:
within the range indicated by the dotted line in the figure below.

When the unit is not in use, the outlet hole should be sealed with the stopper supplied.

Temporary installation: 

The outlet holes can be connected in a number of ways:

In any event, for maximum cooling efficiency the window should be closed as much as possible.

It is advisable :
— to keep the outlet free of any obstruction;
— to lower the blind partly, without obstructing the outlet, thereby reducing exposure to direct sunlight

and indoor/outdoor air exchange.

INSTALLATION FOR HEATING FUNCTION

The unit is simply placed in the room to be heated; there is no need for the discharge hose to be installed.

ELECTRICAL CONNECTIONS

— The mains supply, suitable for domestic electrical appliances, must correspond to the power

requirements of the air conditioner (see rating label).

— Check that the power supply voltage correspond to the voltage shown in the rating label.
— Check that the mains socket is correctly earthed.

N.B.:

 

In the event that the plug supplied with the air-conditioner and complying with European regulations (EEC 7, VII) is not suitable

for your wall socket, make sure that it is replaced with a plug with a capacity of at least 10 A - 250 V (IMQ) that is also suitably earthed.
Remove the power cable from the storage compartment at the back of the unit and plug it into the socket.

THIS APPLIANCE IS MANUFACTURED TO COMPLY WITH THE RADIO INTERFERENCE REQUIRE-
MENTS PROVIDED BY DIRECTIVE EN 55014 EEC.

fixed
 hook

min.

cm 30

max.

cm 120

Summary of Contents for PAC 30

Page 1: ...time and effort to read this manual carefully Becoming familiar with the Pinguino is an essential step if you are to benefit fully from its exceptional qualities during both installation and actual us...

Page 2: ...AC 30 ELECTRONIC can also be used as a heater during the winter months The PAC 30 ELECTRONIC sets the temperature automatically TECHNICAL DATA Tab 1 IDEAL OPERATING CONDITIONS AIR CONDITIONING FUNCTIO...

Page 3: ...trol panel Programmer timer Water container Castors Castor stops Water collecting tray Water container compartment door Air filter Air intake grid Warranty envelope Exhaust hose compartment Power cabl...

Page 4: ...OF ACCESSORIES Tab 4 PARTS SUPPLIED DESCRIPTION Exhaust hose Stopper flange Castor stop De scaling fluid Window nozzle Suction cup set 1 1 2 1 1 1 ACCESSORY CHECK Check that all parts listed in Table...

Page 5: ...safety switch Air entering the room through door and window cracks is normally sufficient If necessary leave a door slightly ajar a gap of approx 1 cm is adequate The unit can also be used as a tempo...

Page 6: ...arge hose to be installed ELECTRICAL CONNECTIONS The mains supply suitable for domestic electrical appliances must correspond to the power requirements of the air conditioner see rating label Check th...

Page 7: ...f the room number of people present etc On average it will last approximately 7 to 10 hours When the container is empty the appliance automatically changes function from water to air At the same time...

Page 8: ...exception of the partially opened window necessary for temporary installation the room is well shaded from direct sunlight by drawing curtains and or partially lowering blinds or shutters to avoid ex...

Page 9: ...wer failure the programmer stops the clock is then slow and must be re set The Pinguino can be used for either AIR COOLING or HEATING The unit can be used in either programmed or non programmed mode P...

Page 10: ...Theheat ing signal lamp comes on When the room tempeture has reached the desired level movetheslidingther mostat control gradually to the min position the unit switches off and the heat ing signal la...

Page 11: ...air conditioner in oily or sulphurous atmospheres or near sources of heat Before moving the air conditioner empty the water from the collecting tray through the drainage tube Never place hot or heavy...

Page 12: ...result to paintwork and plastic CLEANING COLLECTING TRAY The collecting tray should be cleaned at least once a month to prevent dirt from accumulating after prolonged use 1 Switch off the appliance an...

Page 13: ...thermostat on the heating element has been activated to reset the unit disconnect it from mainsforafewminutes eliminatethe cause of overheating and then re connect check whether discharge of air to o...

Page 14: ...nit c Leave the air conditioner to operate for about half an hour d Drain away all the fluid left in the tray and rinse thoroughly The drainage tube should be open and the appliance switched on during...

Reviews: