PROBLEM

CAUSE

REMEDY

The air-conditioner
functions for only
short periods as
safety has been
enabled.
The function OK
signal lamp flashes.

Exhaust hose is blocked

Exhaust hose is bent

Condensator fan is blocked

There are discrepancies in the control card

General switch
keeps activating

switch off appliance and contact Serv-
ice Centre

The appliance works
but does not cool
the environment
sufficiently

close the window

remove heat source

reconnect tube

lower thermostat setting

clean filter

The air-conditioner
does not work

Window open

Source of heat in room (heater, lamp, etc.) or
room is overcrowded

Exhaust hose is disconnected

Thermostat regulated too high

Air filter clogged

The capacity of the conditioner is not ad-
equate for the size of the room

The appliance does
not heat the environ-
ment sufficiently

The safety thermostat on the heating element
has been activated

to reset the unit, disconnect it from
mains for a few minutes, eliminate the
cause of overheating and then re-
connect.

check whether discharge of air to
outside is obstructed in any way.
Press the ON/OFF pushbutton to start
up the unit again.

straighten it

contact Service Centre

contact Service Centre

TROUBLESHOOTING

A malfunction or defect may only be the result of a minor problem which can be easily resolved without
assistance. Look through this checklist therefore, before contacting the Authorised Service Centre
operating in your area.

pilot lamp      is OFF
- power failure
- plug is disconnected

• Memo Control 

signal lamp is flashing

- three minutes have not elapsed since unit

last switched off

Signal lamp flashing

- air-conditioning function: 

room tempera-

ture below set level

Signal lamp flashing

- heating function:

  room temperature ex-

ceeds set level

wait

connect plug

wait three minutes

turn thermostat cursor slowly to maxi-
mum cold

turn thermostat cursor slowly to maxi-
mum hot

Summary of Contents for PAC 30

Page 1: ...time and effort to read this manual carefully Becoming familiar with the Pinguino is an essential step if you are to benefit fully from its exceptional qualities during both installation and actual us...

Page 2: ...AC 30 ELECTRONIC can also be used as a heater during the winter months The PAC 30 ELECTRONIC sets the temperature automatically TECHNICAL DATA Tab 1 IDEAL OPERATING CONDITIONS AIR CONDITIONING FUNCTIO...

Page 3: ...trol panel Programmer timer Water container Castors Castor stops Water collecting tray Water container compartment door Air filter Air intake grid Warranty envelope Exhaust hose compartment Power cabl...

Page 4: ...OF ACCESSORIES Tab 4 PARTS SUPPLIED DESCRIPTION Exhaust hose Stopper flange Castor stop De scaling fluid Window nozzle Suction cup set 1 1 2 1 1 1 ACCESSORY CHECK Check that all parts listed in Table...

Page 5: ...safety switch Air entering the room through door and window cracks is normally sufficient If necessary leave a door slightly ajar a gap of approx 1 cm is adequate The unit can also be used as a tempo...

Page 6: ...arge hose to be installed ELECTRICAL CONNECTIONS The mains supply suitable for domestic electrical appliances must correspond to the power requirements of the air conditioner see rating label Check th...

Page 7: ...f the room number of people present etc On average it will last approximately 7 to 10 hours When the container is empty the appliance automatically changes function from water to air At the same time...

Page 8: ...exception of the partially opened window necessary for temporary installation the room is well shaded from direct sunlight by drawing curtains and or partially lowering blinds or shutters to avoid ex...

Page 9: ...wer failure the programmer stops the clock is then slow and must be re set The Pinguino can be used for either AIR COOLING or HEATING The unit can be used in either programmed or non programmed mode P...

Page 10: ...Theheat ing signal lamp comes on When the room tempeture has reached the desired level movetheslidingther mostat control gradually to the min position the unit switches off and the heat ing signal la...

Page 11: ...air conditioner in oily or sulphurous atmospheres or near sources of heat Before moving the air conditioner empty the water from the collecting tray through the drainage tube Never place hot or heavy...

Page 12: ...result to paintwork and plastic CLEANING COLLECTING TRAY The collecting tray should be cleaned at least once a month to prevent dirt from accumulating after prolonged use 1 Switch off the appliance an...

Page 13: ...thermostat on the heating element has been activated to reset the unit disconnect it from mainsforafewminutes eliminatethe cause of overheating and then re connect check whether discharge of air to o...

Page 14: ...nit c Leave the air conditioner to operate for about half an hour d Drain away all the fluid left in the tray and rinse thoroughly The drainage tube should be open and the appliance switched on during...

Reviews: