11
room volume
air vent necessary (effective area)
6 m
3
to 9 m
3
65 cm
2
6 m
3
to 9 m
3
35 cm
2
Greater than 11 m
3
no air vent necessaIy
A room 6 m
3
to 11 m
3
with a door
no air vent necessary
opening to the outside
All rooms require an openable window or equivalent, while some rooms require a permanent
vent in addition to a window that can be opened.
This unit must not be used in a room with less than 6 m
3
.
Mains gas must be connected by qualified
personnel in compliance with the
regulations in force.
The installer will be responsible for complying with
the safety regulations.
The cooking hob is supplied with an elbow
connection as figure 7 and is
adjusted to work with mains gas.
The above requirements allow also for use of a gas oven and grill but if there
are other gas burning appliances in the same room, consult a qualified engineer.
Connecting to the gas supply
Connect the gas supply pipe to the hob (see Fig. 7) and check that there are no leaks
at any of the joints. Use soapy water. NEVER USE A NAKED FLAME.
figure 7
Ventilation (gas hob)
Gas connection
De Longhi continually strive to improve their products.
For this reason we reserve the right to change speciflcations without prior notice.