26
REGULATION OF THE MINIMUM FLAME
This needs to be done only for the oven burner (the grill is a fixed capacity) by act-
ing on the thermostat.
Considering that in the minimum position the flame must have a length of about 4
mm and must remain lit even with a brusque passage from the maximum position
to that of minimum.
The flame adjustment is done in the following way:
✓
Light the oven burner by turning the knob on position
.
✓
Let the oven pre-heat for about 10 minutes, then take the knob to position
(minimum) to operate at by-pass flow.
✓
Remove the thermostat knob and by means of a thin screwdriver pass by the hole
in the facia panel to unscrew of 3 turns the by-pass screw
G
(fig. 5.10)
✓
Slowly tighten the by-pass screw
G
(fig. 5.10) until you get a flame of 3-4 mm
long.
✓
Turn off the burner and reassemble the knob.
✓
After regulation (always with oven hot and the oven door closed) check the sta-
bility of the flame with a passage from the maximum to minimum position.
The grill is a fixed capacity and does not need be adjusted.
N.B.:
For Liquid gas (G 30/G 31) the screw
G
must be tightened thoroughly.
G
Fig. 5.10
Summary of Contents for DGS 61 ST
Page 30: ...30...
Page 32: ...Cod 1103217 3...