19
LOCATION
The appliance may be installed in a kitchen, Kitchen/diner or a bed sitting room, but
not in a room or space containing a bath or a shower.
– The appliance must not be installed in a bed-sitting room of less than 20 m3.
– The appliance is designed and approved for domestic use only and should not be
installed in a commercial, semi commercial or communal environment.
– Your product will not be guaranteed if installed in any of the above environments
and could affect any third party or public liability insurances you may have.
PROVISION FOR VENTILATION
✓
The appliance should be installed into a room or space with an air supply in accor-
dance with BS 5440-2: 2000.
✓
For rooms with a volume of less than 5 m
3
- permanent ventilation of 100 cm
2
free area will be required.
✓
For rooms with a volume of between 5 m
3
and 10 m
3
a permanent ventilation of
50 cm
2
free area will be required unless the room has a door which opens direct-
ly to the outside air in which case no permanent ventilation is required.
✓
For rooms with a volume greater than 10 m
3
- no permanent ventilation is required.
NB. Regardless of room size, all rooms containing the appliance must have
direct access to the outside air via an openable window or equivalent.
✓
Where there are other fuel burning appliances in the same room, BS 5440-2: 2000
should be consulted to determine the correct amount of free area ventilation require-
ments.
✓
The above requirements allow also for use of a gas oven and grill but if there are
other gas burning appliances in the same room, consult a qualified engineer.