12
TABLE FOR THE CHOICE OF THE INJECTORS
Natural gas
Universal LPG
Test Point Pressure [kPa]
1.0
2.75
BURNER
Auxiliary (A)
0.85
3.60
0.53
3.60
Medium-speed burner (SR)
1.12
6.30
0.70
6.30
Rapid burner (R)
1.45
10.30
0.91
10.80
Triple-ring burner (TR)
1.65
13.00
0.95
11.90
Fish burner (PS)
1.12
6.30
0.70
6.30
Gas
Consumption
[MJ/h]
Injector
Orifice Dia.
[mm]
Gas
Consumption
[MJ/h]
Injector
Orifice Dia.
[mm]
INSTALLATION WITH A FLEXIBLE HOSE ASSEMBLY
■
If this appliance has to be installed with a hose assembly, the installer shall refer
to the network operator or gas supplier for confirmation of the gas type, if in
doubt.
■
The gas supply connection point shall be accessible when the appliance is
installed.
■
Installation with a flexible hose assembly shall be carried out by using a hose with
internal diameter of 10 mm minimum.
The thread connection shall be Rp 1/2” (ISO 7-1) male.
■
IMPORTANT WARNING
: After connection the installer must check that the hose
is not kinked, subjected to abrasion or permanently deformed.
The installer must check also that the hose is not near (or in contact) with any hot
surfaces e.g. base of metal hotplate, underbench oven etc.
■
The hose assembly shall be as short as practicable and comply with relevant AS
5601/601 requirements.
■
IMPORTANT WARNING
: The installer shall ensure the hose assembly is
restrained from accidental contact with the flue outlet of an underbench oven.
Summary of Contents for DEGH70W
Page 32: ...Cod 1103187 ß1 ...