7
750 mm
50 mm min
100 mm min
500 mm
450 mm
The installation shall comply
with the dimensions in Figures
3 and 4, bearing in mind that:
■
A
minimum clearance
of 20 mm
has to be
kept between the bottom
of the cooking hob and
the top of an appliance
or a shelf.
To ensure this clear-
ance mount the spac-
ers supplied with the
appliance as shown in
the figure 5.
■
A
partition
between the
base of the hob and the
cupboard below
should
be fitted 100 mm
below the workbench
surface if the cupboard is
to be used for storage.
Figure 4
20 mm
Double-sided
adhesive tape
Spacer
■
Overhead clearances
-
In no case shall the clear-
ance between the highest
part of the hob and a
range hood be less than
600 mm, or for an over-
head exhaust fan, 750
mm. Any other down-
ward facing combustible
surface less than 600 mm
above the highest part of
the hob shall be protect-
ed for the full width and
depth of the cooking sur-
face area in accordance
with local regulations in
force. However, in no
case shall this clearance
to any surface be less
than 450 mm.
Figure 5
Summary of Contents for DE30W
Page 22: ...22...
Page 24: ...cod 1103202 1...