background image

5. Check the minimum burner setting by quickly rotating the gas control knob from

the maximum to the minimum position, the flame must not go out. If adjust-
ment is required carry out the “minimum burner setting adjustment" procedure
described below.

6. If satisfactory performance cannot be obtained, the installer shall check the instal-

lation and notify the local gas supply authority for a gas supply problem, or if it
is an appliance problem, our Customer Service Centre should be called to obtain
the nearest authorized Delonghi Service Agent.

7. 

Where the appliance data plate cannot be easily read with the appliance in the

installed position the duplicate data plate must be attached to adjacent surface
and the duplicate Natural gas / ULPG conversion label should also be included
where a Natural gas / ULPG conversion has been completed.

Figure 10

10

 If this appliance has to be installed with  a hose  assembly,  the installer shall

refer to the network operator or gas supplòier for confirmation of the gas type,
if in doubt.

INSTALLATION WITH A FLEXIBLE HOSE ASSEMBLY

 The  gas supply connection  point shall be accessible  when the appliance  is

installed.

 Installation  with a flexible hose assembly  shall be carried out  by using a hose

with internal diameter of 16 mm minimum.
The thread connection shall be Rp 1/2" (ISO 7-1) male.

 IMPORTANT WARNING: After connection the installer must check that the hose

is not kinked, subjected to abrasion or permanently deformed.
The installer must check also that the hose is not near (or in contact) with any
hot surfaces e.g. base of metal hotplate, underbench oven etc.

 The hose assembly shall be as short as practicable  and comply  with relevant

AS 5601/601 requirements.

 IMPORTANT WARNING: The installer shall ensure the hose assembly is restrained

from accidental contact with the flue outlet of an underbench oven.

Summary of Contents for DE30W

Page 1: ...distributed by D Longhi Pty Ltd INSTALLATION and SERVICE INSTRUCTIONS USE and CARE INSTRUCTIONS BUILT IN GAS HOBS Models DE30W DE320G...

Page 2: ...et in a safe place It may be useful in future either to yourself or to others in the event that doubts should arise relating to its operation This appliance must be used only for the task it has expli...

Page 3: ...cked the appliance check to ensure that it is not damaged In case of doubt do not use it and consult your supplier or a professionally qualified technician Packing elements i e plastic bags polystyren...

Page 4: ...h safety standards If the appliance is supplied without plug fit a standard plug which is suitable for the power consumed by the appliance The wires in the power cable are coloured in accordance with...

Page 5: ...ng the power cord must be done by a qualified electrician in accordance with the instructions supplied by the manufacturer and in compliance with established electrical regulations 5 N L M PA A CA 1 B...

Page 6: ...lations code DIMENSIONS Note Also refer to Figure 3 General Dimensions Width 288 mm Depth 510 mm Depth Below Mounting Surface 30 mm Cut out Dimensions Width 270 mm Depth 490 mm Important note This app...

Page 7: ...should be fitted 100 mm below the workbench surface if the cupboard is to be used for storage Figure 4 20 mm Double sided adhesive tape Spacer Overhead clearances In no case shall the clear ance betw...

Page 8: ...periphery of the nearest burner to any vertical combustible surface is less than 200 mm the surface shall be protected in accordance with local regulations in force to a height of not less than 150 mm...

Page 9: ...or Thread tight use suitable seal Test point adaptor Gasket Brass conical adaptor Thread tight use suitable seal Gas regulator Gas inlet pipe 9 Test point Test point 1 After connecting the gas supply...

Page 10: ...been completed Figure 10 10 If this appliance has to be installed with a hose assembly the installer shall refer to the network operator or gas suppl ier for confirmation of the gas type if in doubt...

Page 11: ...e appliance TABLE FOR THE CHOICE OF THE INJECTORS Natural Gas ULPG Test Point 1 0 2 75 Pressure kPa Burner Injector Orifice Gas Consumption Injector Orifice Gas Consumption mm MJ h mm MJ h Semi rapid...

Page 12: ...the cooktop has been convert ed for use with Natural gas ULPG supplied with the Natural gas ULPG conversion kit A second Natural gas ULPG conversion label should also be affixed to an adjacent surfac...

Page 13: ...te setting is described below For taps with adjusting screw inside the shaft fig 13 using a screwdriver max diameter 3 mm turn the screw inside the tap shaft until the flame setting is correct For tap...

Page 14: ...Fig 16 The appliance is class 3 rated COOKING POINT 5 Triple ring burner 13 30 MJ h NG 11 90 MJ h ULPG CONTROL PANEL DESCRIPTION 6 Triple ring burner control knob 2 BURNER COOKING HOB Fig 15 The appli...

Page 15: ...e of the gas burners follow the procedure LIGHTING GAS BURNERS on page 16 To reduce the gas flow to minimum rotate the knob further anti clockwise to point the indicator towards the small flame symbol...

Page 16: ...alve to the desired position If the burner flame should go out the safety valve will automatically stop the gas flow To re light the burner first turn the oven control knob to position l wait for at l...

Page 17: ...quickly and the smallest for stews and sauces Always ensure that you use the correct size of saucepan For fast boiling make sure the flame just reaches the edge of the pan Flames going up the side of...

Page 18: ...ormal non abrasive detergents available on the market or else a little warm vinegar CLEANING THE HOB Spillage on the hob can usually be removed by a damp soapy cloth More obsti nate stains can be remo...

Page 19: ...d see figs 22 and 26 failure to do so can cause serious problems Check that the electrode S fig 22 is always clean to ensure trouble free sparking In the models with safety device check that the probe...

Page 20: ...rner must be correctly positioned see fig 23 the burner rib must be located in position as shown by the arrow Then position the cap A and the ring B fig 24 25 The burner correctly positioned must not...

Page 21: ...an and dry 240 VAC power supply is connected Contact the local gas utility or our Customer Service Centre to obtain the nearest Authorized Service Agent You can smell gas when all burners are turned o...

Page 22: ...22...

Page 23: ...t are given as simply indicative The manufacturer reserves the right considering the characteristics of the models described here at any time and without notice to make eventual necessary modification...

Page 24: ...cod 1103202 1...