5. Check the minimum burner setting by quickly rotating the gas control knob from
the maximum to the minimum position, the flame must not go out. If adjust-
ment is required carry out the “minimum burner setting adjustment" procedure
described below.
6. If satisfactory performance cannot be obtained, the installer shall check the instal-
lation and notify the local gas supply authority for a gas supply problem, or if it
is an appliance problem, our Customer Service Centre should be called to obtain
the nearest authorized Delonghi Service Agent.
7.
Where the appliance data plate cannot be easily read with the appliance in the
installed position the duplicate data plate must be attached to adjacent surface
and the duplicate Natural gas / ULPG conversion label should also be included
where a Natural gas / ULPG conversion has been completed.
Figure 10
10
■
If this appliance has to be installed with a hose assembly, the installer shall
refer to the network operator or gas supplòier for confirmation of the gas type,
if in doubt.
INSTALLATION WITH A FLEXIBLE HOSE ASSEMBLY
■
The gas supply connection point shall be accessible when the appliance is
installed.
■
Installation with a flexible hose assembly shall be carried out by using a hose
with internal diameter of 16 mm minimum.
The thread connection shall be Rp 1/2" (ISO 7-1) male.
■
IMPORTANT WARNING: After connection the installer must check that the hose
is not kinked, subjected to abrasion or permanently deformed.
The installer must check also that the hose is not near (or in contact) with any
hot surfaces e.g. base of metal hotplate, underbench oven etc.
■
The hose assembly shall be as short as practicable and comply with relevant
AS 5601/601 requirements.
■
IMPORTANT WARNING: The installer shall ensure the hose assembly is restrained
from accidental contact with the flue outlet of an underbench oven.
Summary of Contents for DE30W