background image

or damaged. In any case replace the tube every 5 years. 
When connecting the pressure regulator to the gas bottle avoid undue twisting of the flexi-
ble tubing.
A 28 ÷ 30 mbar (11.2 in w.g.) pressure regulator for Butane or Propane complying to local
standard must be connected to the appliance with the above tubing, using suitable tube
clips.

Ventilation

USE ONLY IN A WELL VENTILATED ROOM

Adequate ventilation must be provided in rooms in which the heater is used. This ensures
removal of the products of combustion and allows the entry of replacement air.
The following table shows the smallest size of room suitable for each heat setting and the
dimensions of the aperture which  must be provided equally divided between high and low
level, according with the maximum, medium or minimum power.

Safety guard

The guard is to prevent risk of fire and no part of it should be permanently removed.

It does not give full protection for young children or the infirm.

OPERATING INSTRUCTIONS

Lighting the heater

1. Turn on the gas at the gas bottle tap.
2. FROM « 

● 

» POSITION, fully depress the control knob for 15 seconds and turn to      

(Big Flame) position. (If pilot flame does not ignite return to starting position and repeat).
Continue to fully depress the knob for a further 20 seconds to allow the thermocouple
probe to heat up. Leave control knob in position      (big flame) for 10 minutes then turn
the knob to select the desired setting as follows:

(Big Flame) Maximum Input,                                (Medium Flame) Medium Input,   
(Small Flame)  Low Input

Auxiliary ignition

Should piezoelectric starter fail to work, repeat operation on control knob and  use a match
to light pilot flame.

Tunring off the heater

Turn off the gas bottle tap. 

The Heater will be totally “OFF” only if the tap at the gas bottle is turned off.

Ventilation only

(It can be used together with the
gas burners for an adequate
heat distribution).

OFF

Venti1800W heating

(It can be used together with the
gas burners - 3100 W - for the
fast heating of the room).

Venti900W heating

(It can be used together with the
3000 W gas burners  - for  the
very fast heating of the room).

5

573441 GB  31-01-2001 14:34  Pagina 5