4
bles. If a leak is found, turn the gas off and inform your Dealer. DO NOT use the heater
again until it has been inspected by your Dealer.
NEVER USE MATCHES TO FIND LEAKS.
GENERAL SAFETY INSTRUCTIONS
Gas bottle
Gas Bottle with 15 kg of maximum capacity can be installed.
Changing of gas bottle must not be carried out in the presence of a naked flame.
Use the gas bottle always in upright position. If a screw on regulator is used ensure that the
regulator washer is present and in good condition -replace if in any doubt.
To place the bottle in position, remove the rear panel which faces the inside during tran-
sport, by unfastening the screws; than put the bottle in position and replace the panel.
Do not turn the bottle upside down to use completely its content.
Pressure regulators, rubber tubes and clips
CHECK that tubing is completely over the nozzles at each end of the tubing and that it is
held firmly in place by tube clips (See fig.5). Examine flexible tubing regularly and get
your Dealer to fit new tubing 400 mm long complying to local standard, if perished, worn
fig. 5
Control knob setting
Room Size
Room Aperture
1) Position
big flame
(maximum rate)
30 m
3
75 cm
2
2) Position
medium flame
(medium rate)
23.5 m
3
3) Position
small flame
(low rate)
18.5 m
3
573441 GB 31-01-2001 14:34 Pagina 4