12 www.dellonda.co.uk

•  Each safety buckle has a lock system ; the 

latch in up position locks the buckle, the latch 

in down position unlocks the buckle.

•  Remember covers should be cleaned inside 

and out periodically using a suitable solution 

that includes adequate disinfection.

Water Maintenance

• 

WARNING

 : Poor spa water quality can harm 

your health. Depending on the frequency and 

conditions of use:

• 

The filter cartridge should be regularly cleaned 

(150 hours max.).

• 

The filter cartridge should be replaced every 1 

to 2 months.

•  The spa water should be changed every 15 to 

30 days.

•  Use a water test kit to control the parameters 

of the water before using the spa, or at least 

once a week.

•  Use disinfection products for the spa. The 

treatment products should be used with 

caution and it is imperative to refer to the 

manufacturer instructions.

•  Damage resulting from improper use of 

treatment products is not covered by warranty 

(overdose, shock treatment, ...). 

Water balance;

 

The water balance 

(pH)

 must be maintain 

between 7 and 7.4. 

Water Sanitation;

 

To sanitize the spa water, we suggest using an 

active oxygen-based treatment or bromine 

placed in a floating dispenser. (Not included).

Cleaning and replacing filter 

cartridge

• 

A dirty filter cartridge may contaminate the 

spa water and cause damage to the heating 

function.

1. Unscrew the filter case by turning it counter-

clockwise. Take out the filter cartridge from the 

case.

2. Rinse off the filter cartridge with a garden 

hose. If the filter cartridge remains dirty and 

discoloured, the filter cartridge should be 

replaced.

3. Put back the cleaned filter cartridge into its 

case and screw it to the spa.

Disinfection

•  Water Sanitation:

•  In the absence of automated and continuous 

water treatment (measurement and chemical 

dosage) any manual dosing of chemicals must 

not be performed while bathers are present in 

the spa.

Summary of Contents for DL88

Page 1: ...del No DL88 DL89 DL90 DL91 Thank you for purchasing a Dellonda product Manufactured to a high standard this product will if used according to these instructions and properly maintained give you years...

Page 2: ...correctly and with care for the purpose for which it is intended Failure to do so may cause damage and or personal injury and will invalidate the warranty Keep these instructions safe for future use C...

Page 3: ...del DL89 Water Capacity 1200L 264 gal Inner Dimensions 160 x 70cm Outer Dimensions 204 x 70cm Capacity 4 6 People Bubble Jet Holes 140 Massage Bubble Power 650W Heating Rate 1 5 2 5 C hr Maximum Water...

Page 4: ...helpful aids but they are not substitutes for continuous and competent adult supervision Safety equipment 1 It is recommended to keep rescue equipment e g a lifebuoy by the spa 2 Keep a working phone...

Page 5: ...e unit to electric supply provide a properly located outlet The spa electrical appliance is supplied through a residual current device RCD having a rated residual operating current not exceeding 10mA...

Page 6: ...g hazard foetal damage in pregnant women physical inability to exit the spa and unconsciousness resulting in the danger of drowning Obese persons or persons with a history of heart disease low or high...

Page 7: ...recommended that this heater is wired directly to a fused isolator switch If however a plug is fitted the following applies Fit a new plug according to the following instructions UK only A Connect th...

Page 8: ...areas shall be considered in the cleaning process as well No cleaning agent should flow into the spa or spa water cycle The dirt and cleaning agents shall be rinsed carefully to a drain in the spa ens...

Page 9: ...spa 5 Connect the pump unit then press the massage button to inflate the spa The air flow valve prevents your spa from over inflating 6 Inflate the inflatable spa for about 10 minutes Ensure that the...

Page 10: ...it fills evenly Continue filling the spa to the level indicated Control Panel Functions Once powered up the LED displays the current water temperature automatically The temperature units selector cha...

Page 11: ...rature automatically Maximum heating temperature 40 C 104 F Important After 150 cumulative hours of filtration operations an audible alarm will sound and the LCD display will show the characters CHG f...

Page 12: ...structions Damage resulting from improper use of treatment products is not covered by warranty overdose shock treatment Water balance The water balance pH must be maintain between 7 and 7 4 Water Sani...

Page 13: ...can be cleaned with soap and water Storage NOTE Whenever the spa is emptied the filter should be cleaned and dried where applicable 1 Press the massage button to blow out the water inside the jet hol...

Page 14: ...ctrician to reset the thermal cutout described in next paragraph If this does not solve the problem refer to the box below E6 Not heating and filtering properly alarm sounding Water pressure is not en...

Page 15: ...ait 30 minutes and press the massage button to reactivate Malfunction of the pump unit Call for service if it does not reset Water filtration does not work Filter Cartridge is dirty Clean or Replace t...

Page 16: ...nger required or has reached the end of it s useful life please dispose of it in an environmentally friendly way Drain any fluids if applicable into approved containers in accordance with local waste...

Reviews: