Site Selection
•
WARNING
: Before you proceed to installation
of your spa, please make sure that the location
meets the following conditions :
• A level place in order to avoid any defect,
separation or leakage.
• Wide enough to support the pool and its pump
unit.
•
Able to support more than 500 kg/m².
• Sheltered from the sun and bad weather.
• Clean and free from sharp objects.
• Devoid of aggressive vegetation on the
ground.
•
For above ground portable spas without floor
insulation, consider using an insulating ground
sheet underneath the spa to minimize heat
loss through the bottom of the spa.
• Barefoot areas and relaxing areas shall be
considered in the cleaning process as well.
No cleaning agent should flow into the spa or
spa water cycle. The dirt and cleaning agents
shall be rinsed carefully to a drain in the spa
ensuring local waste regulations are met.
• Failure to comply with these rules may result
in property damage or personal injury.
RCD Test
•
WARNING
: The
RCD
plug must be tested
before each use.
• DO NOT
use if
RCD
test fails.
• 1. Insert the plug into the power outlet.
• 2. Press the «
RESET
» button, the indicator light
turns red.
• 3. Press the «
TEST
» button, the indicator light
turns off.
• 4. Press the «
RESET
» button, the indicator light
turns red. The
RCD
works properly.
Earthing
• You are recommended to use the services of a
qualified electrician to ensure that the spa is
electrically earthed by using a copper
conductor of at least 2.5 mm² cross section.