background image

www.dellonda.co.uk 7

maximum safe temperature.

Electrical Safety

• 

WARNING

! It is the responsibility of the owner 

and the operator to read, understand and 

comply with the following:

•  You must check all electrical products, before 

use, to ensure that they are safe. You must 

inspect power cables, plugs, sockets and any 

other connectors for wear or damage. You 

must ensure that the risk of electric shock is 

minimised by the installation of appropriate 

safety devices. A Residual Current Circuit 

Breaker (

RCCB

) should be incorporated in the 

main distribution board. You must also read 

and understand the following instructions 

concerning electrical safety.

•  Ensure that cables are always protected 

against short circuit and overload.

•  Regularly inspect power supply cables and 

plugs for wear or damage and check all 

connections to ensure that none are loose.

•  Ensure that the voltage marked on the 

appliance matches the power supply to be  

used and that the plug is fitted with the correct 

fuse - see fuse rating at right.

• 

DO

 

NOT

 use worn or damaged cables, plugs or 

connectors. Have any faulty item repaired or  

replaced immediately by a competent 

electrician.

•  It is recommended that this heater is wired 

directly to a fused isolator switch. If however, a 

plug is fitted, the following applies:

•  Fit a new plug according to the following 

instructions (

UK

 only).

A) Connect the GREEN/YELLOW earth wire to 

Recommended fuse rating

13 Amp

the earth terminal ‘E’.

B) Connect the BROWN live wire to the live 

terminal ‘L’.

C) Connect the BLUE neutral wire to the neutral 

terminal ‘N’.

D) After wiring, check that there are no bare 

wires, that all wires have been correctly 

connected and that the cable restraint is tight.

•  A wire connector is provided on this unit to 

connect a minimum 8 

AWG

 (8.4 mm2), 6 

AWG

 

(13.3mm2) solid copper conductor between 

this unit and any metal equipment, metal 

enclosures of electrical equipment, metal 

water pipe, or conduit within 5 feet (1.5 m) of 

the unit.

Installation

• 

WARNING

 : Spas installed on inadequately 

level surfaces are subject to leaking. Such 

leaking can cause property and or surface 

damage or collapse, which can result in 

property damage or serious injury for those in 

or around the spa area.

• 

CAUTION

 : Please choose your set-up 

area carefully as lawn and other desirable 

vegetation underneath the ground sheet (if 

applicable) will die. Furthermore, try to avoid 

setting the ground sheet in areas prone to 

aggressive plant and weed species, as they 

Summary of Contents for DL16

Page 1: ...del No DL16 DL17 DL23 DL24 Thank you for purchasing a Dellonda product Manufactured to a high standard this product will if used according to these instructions and properly maintained give you years...

Page 2: ...correctly and with care for the purpose for which it is intended Failure to do so may cause damage and or personal injury and will invalidate the warranty Keep these instructions safe for future use C...

Page 3: ...del DL17 Water Capacity 1200L 264 gal Inner Dimensions 160 x 70cm Outer Dimensions 204 x 70cm Capacity 4 6 People Bubble Jet Holes 140 Massage Bubble Power 650W Heating Rate 1 5 2 5 C hr Maximum Water...

Page 4: ...helpful aids but they are not substitutes for continuous and competent adult supervision Safety equipment 1 It is recommended to keep rescue equipment e g a lifebuoy by the spa 2 Keep a working phone...

Page 5: ...e unit to electric supply provide a properly located outlet The spa electrical appliance is supplied through a residual current device RCD having a rated residual operating current not exceeding 10mA...

Page 6: ...of impending hazard foetal damage in pregnant women physical inability to exit the spa and unconsciousness resulting in the danger of drowning Obese persons or persons with a history of heart disease...

Page 7: ...a competent electrician It is recommended that this heater is wired directly to a fused isolator switch If however a plug is fitted the following applies Fit a new plug according to the following inst...

Page 8: ...eas and relaxing areas shall be considered in the cleaning process as well No cleaning agent should flow into the spa or spa water cycle The dirt and cleaning agents shall be rinsed carefully to a dra...

Page 9: ...spa 5 Connect the pump unit then press the massage button to inflate the spa The air flow valve prevents your spa from over inflating 6 Inflate the inflatable spa for about 10 minutes Ensure that the...

Page 10: ...it fills evenly Continue filling the spa to the level indicated Control Panel Functions Once powered up the LED displays the current water temperature automatically The temperature units selector cha...

Page 11: ...rature automatically Maximum heating temperature 40 C 104 F Important After 150 cumulative hours of filtration operations an audible alarm will sound and the LCD display will show the characters CHG f...

Page 12: ...structions Damage resulting from improper use of treatment products is not covered by warranty overdose shock treatment Water balance The water balance pH must be maintain between 7 and 7 4 Water Sani...

Page 13: ...can be cleaned with soap and water Storage NOTE Whenever the spa is emptied the filter should be cleaned and dried where applicable 1 Press the massage button to blow out the water inside the jet hol...

Page 14: ...ctrician to reset the thermal cutout described in next paragraph If this does not solve the problem refer to the box below E6 Not heating and filtering properly alarm sounding Water pressure is not en...

Page 15: ...ait 30 minutes and press the massage button to reactivate Malfunction of the pump unit Call for service if it does not reset Water filtration does not work Filter Cartridge is dirty Clean or Replace t...

Page 16: ...nger required or has reached the end of it s useful life please dispose of it in an environmentally friendly way Drain any fluids if applicable into approved containers in accordance with local waste...

Reviews: