INSTALLATION INFORMATION
MODEL CAPACITY
9k
12k
15/18k
22/24k
Liquid pipe diameter
1/4” (Φ6) 1/4” (Φ6)
1/4” (Φ6) 3/8”
(Φ9.52)
Gas pipe diameter
3/8”
(Φ9.52)
3/8”
(Φ9.52)
1/2”
(Φ12)
1/2”
(Φ12)
5/8”
(Φ15.88)
Length of pipe with standard charge
3m
3m
3m
4m
4m
Maximum distance between indoor and out-
door unit
15m
15m
15m
15m
15m
Additional refrigerant charge
20g/m
20g/m
20g/m
30g/m
30g/m
Max level diff. between indoor and outdoor
unit
5m
5m
5m
5m
5m
Type of refrigerant
R410A
R410A
R410A
R410A
R410A
MODEL
9k
12k
18/22k
24k
Power supply cable
N
1.0mm2
(1.5mm2)
AWG18
(AWG16)
1.0mm2
(1.5mm2)
AWG18
(AWG16)
1.5mm2
AWG16
2.5mm2
AWG14
L
1.0mm2
(1.5mm2)
AWG18
(AWG16)
1.0mm2
(1.5mm2)
AWG18
(AWG16)
1.5mm2
AWG16
2.5mm2
AWG14
E
1.0mm2
(1.5mm2)
AWG18
(AWG16)
1.0mm2
(1.5mm2)
AWG18
(AWG16)
1.5mm2
AWG16
2.5mm2
AWG14
Connection supply cable
N
1.0mm2
(1.5mm2)
1.0mm2
(1.5mm2)
1.5mm2
0.75mm2
L
1.0mm2
(1.5mm2)
1.0mm2
(1.5mm2)
1.5mm2
0.75mm2
1
1.0mm2
(1.5mm2)
1.0mm2
(1.5mm2)
1.5mm2
0.75mm2
1.0mm2
(1.5mm2)
1.0mm2
(1.5mm2)
1.5mm2
0.75mm2
Cable Wires Specification