![Dell UCS-51 User Manual Download Page 12](http://html.mh-extra.com/html/dell/ucs-51/ucs-51_user-manual_79831012.webp)
10
Overview
About RAID
RAID is a group of multiple independent physical disks that provide high performance by increasing the
number of drives used for saving and accessing data. A RAID disk subsystem improves I/O performance
and data availability. The physical disk group appears to the host system as a single storage unit or as
multiple logical units. Data throughput improves because multiple disks can be accessed simultaneously.
RAID systems also improve data storage availability and fault tolerance.
RAID Levels
Integrated Striping or RAID 0 uses disk striping to provide high data throughput, especially for large files
in an environment that requires no data redundancy.
Integrated Mirroring or RAID 1 uses disk mirroring so that data written to one physical disk is
simultaneously written to another physical disk. This is good for small databases or other applications
that require small capacity, but complete data redundancy.
NOTICE:
Lost data on an Integrated Striping virtual disk cannot be recovered in the event of a physical disk failure.
RAID Terminology
Integrated Striping
Integrated Striping (RAID 0) allows you to write data across multiple physical disks instead of just one
physical disk. Integrated Striping involves partitioning each physical disk storage space into 64 KB stripes.
These stripes are interleaved in a repeated sequential manner. The part of the stripe on a single physical
disk is called a stripe element.
For example, in a four-disk system using only Integrated Striping, segment 1 is written to disk 1, segment 2
is written to disk 2, and so on. Integrated Striping enhances performance because multiple physical disks
are accessed simultaneously, but Integrated Striping does not provide data redundancy. Figure 1-2 shows
an example of Integrated Striping.
Figure 1-2.
Example of Integrated Striping (RAID 0)
Stripe element 1
Stripe element 5
Stripe element 9
Stripe element 2
Stripe element 6
Stripe element 10
Stripe element 3
Stripe element 7
Stripe element 11
Stripe element 4
Stripe element 8
Stripe element 12
YD912bk1.book Page 10 Monday, April 2, 2007 4:39 PM
Summary of Contents for UCS-51
Page 2: ...YD912bk1 book Page 2 Monday April 2 2007 4 39 PM ...
Page 14: ...12 Overview YD912bk1 book Page 12 Monday April 2 2007 4 39 PM ...
Page 20: ...18 Hardware Installation YD912bk1 book Page 18 Monday April 2 2007 4 39 PM ...
Page 44: ...42 Updating the Firmware YD912bk1 book Page 42 Monday April 2 2007 4 39 PM ...
Page 52: ...50 Regulatory Notices YD912bk1 book Page 50 Monday April 2 2007 4 39 PM ...
Page 53: ...Regulatory Notice 51 YD912bk1 book Page 51 Monday April 2 2007 4 39 PM ...
Page 54: ...52 Regulatory Notices YD912bk1 book Page 52 Monday April 2 2007 4 39 PM ...
Page 55: ...Regulatory Notice 53 YD912bk1 book Page 53 Monday April 2 2007 4 39 PM ...
Page 56: ...54 Regulatory Notices YD912bk1 book Page 54 Monday April 2 2007 4 39 PM ...
Page 58: ...56 Regulatory Notices YD912bk1 book Page 56 Monday April 2 2007 4 39 PM ...
Page 59: ...Regulatory Notice 57 YD912bk1 book Page 57 Monday April 2 2007 4 39 PM ...
Page 60: ...58 Regulatory Notices YD912bk1 book Page 58 Monday April 2 2007 4 39 PM ...
Page 66: ...64 Glossary YD912bk1 book Page 64 Monday April 2 2007 4 39 PM ...