Installing Enclosure Components
37
Figure 3-8.
Removing and Replacing the Control Panel
6
Using a Torx T10 driver, remove all 16 screws from the front faceplate of the enclosure as shown in
Figure 3-8.
7
Remove the front faceplate from the enclosure and place it on a flat, secure surface.
8
Slide the control panel assembly straight out from its connector on the backplane (see Figure 3-8).
Installing the Control Panel
1
Align the top and bottom tabs on the control panel with the insert slots on the edge of the chassis (see
Figure 3-8).
2
Slide the control panel fully into the slot, making sure that its connector engages into the matching
backplane connector (see Figure 3-8). Also, make sure the guide tab on the control panel is fully
inserted into the mounting slot on the backplane.
3
Replace the front faceplate and re-attach the 16 screws that hold it in place.
4
Re-install any drives you removed (see "Removing and Installing Drives").
5
Push the enclosure all the way back into the rack and tighten the thumbscrews securely.
6
Reconnect power cables to the enclosure and power it back on.
7
Power on the host server.