![Dell PowerEdge T130 Owner'S Manual Download Page 10](http://html.mh-extra.com/html/dell/poweredge-t130/poweredge-t130_owners-manual_85535010.webp)
Icon
Description
Condition
Corrective action
Hard drive
indicator
The indicator flashes amber
if there is a hard drive error.
Check the System Event Log to determine
the hard drive that has an error. Run the
appropriate Online Diagnostics test. Restart
the system and run embedded diagnostics
(ePSA). If the hard drives are configured in a
RAID array, restart the system and enter the
host adapter configuration utility program.
Electrical
indicator
The indicator flashes amber
if the system experiences an
electrical error (for example,
voltage out of range, or a
failed power supply unit
(PSU) or voltage regulator).
Check the System Event Log or system
messages for the specific issue. If it is due
to a problem with the PSU, check the LED
on the PSU. Reseat the PSU. If the problem
persists, see
Getting help
.
Temperature
indicator
The indicator flashes amber
if the system experiences a
thermal error (for example, a
temperature out of range or
fan failure).
Ensure that none of the following
conditions exist:
• A cooling fan is removed or has failed.
• System cover, memory module blank,
or back filler bracket is removed.
• Ambient temperature is too high.
• External airflow is obstructed.
See
Getting help
.
10