26
About Your System
Operating system not
found
See "Troubleshooting a
Hard Drive" on page 120.
If the problem persists,
see "Getting Help" on
page 137.
PCI BIOS failed to
install
BIOS checksum failure
detected.
Ensure that all network
cards and connections
are functioning properly.
See "Troubleshooting
System Memory" on
page 114."
If the problem persists,
see "Getting Help" on
page 137."
Plug and play
configuration error
An attached device is
improperly configured.
See "Troubleshooting
Your System" on
page 103.
Read fault
The operating system
cannot read from the
diskette or hard drive,
the system could not
find a particular sector
on the disk, or the
requested sector is
defective.
See "Troubleshooting a
Diskette Drive" on
page 116 or
"Troubleshooting a Hard
Drive" on page 120.
Requested sector not
found
The operating system
cannot read from the
diskette or hard drive,
the system could not
find a particular sector
on the disk, or the
requested sector is
defective.
See "Troubleshooting a
Diskette Drive" on
page 116 or
"Troubleshooting a Hard
Drive" on page 120.
Table 1-6.
System Messages
(continued)
Message
Causes
Corrective Actions