Error Code Error Message
Error Cause
Recovery Method
0012h
CMOS Date/Time Not
Set
Indicate invalid
date/time in CMOS
diagnostic status byte
Reset Date/Time
0040h
Refresh Timer Test
Failed
Unrecoverable system-
board failure
Board repair
0041h
Display Memory Test
Failed
Unrecoverable system-
board failure
Board repair
0044h
DMA Controller Error Unrecoverable system-
board failure
Board repair
0045h
DMA-1 Error
Unrecoverable system-
board failure
Board repair
0046h
DMA-2 Error
Unrecoverable system-
board failure
Board repair
0048h
Password Check Failed Preboot user password
violation
Clear password by
switch
004Ah
ADM Module Error
Unspecified
Board repair
004Bh
Language Module Error
7
Unspecified
Board repair
005Dh
S.M.A.R.T. Command
Failed
S.M.A.R.T. Status BAD,
Backup and Replace
HDD/ATAPI/IDE device
failure
Change HDD
005Eh
Password Check Failed Other preboot password
violation
Clear password by
switch
0060h
Primary Master Hard
Disk Error
HDD/ATAPI/IDE device
failure
Change HDD
0061h
Primary Slave Hard Disk
Error
HDD/ATAPI/IDE device
failure
Change HDD
0062h
Secondary Master Hard
Disk Error
HDD/ATAPI/IDE device
failure
Change HDD
0063h
Secondary Slave Hard
Disk Error
HDD/ATAPI/IDE device
failure
Change HDD
0080h
Primary Master Drive-
ATAPI Incompatible
HDD/ATAPI/IDE device
failure
Change HDD
0081h
Primary Slave Drive-
ATAPI Incompatible
HDD/ATAPI/IDE device
failure