![Dell PowerConnect B-MLXe Series Getting Started Manual Download Page 17](http://html.mh-extra.com/html/dell/powerconnect-b-mlxe-series/powerconnect-b-mlxe-series_getting-started-manual_84533017.webp)
PowerConnect B-MLXe Getting Started Guide
15
53-1001995-01
NOTE
The PowerConnect B-MLXe Series modules are dedicated, which means that you must install them in the
PowerConnect B-MLXe Series chassis only. For example, if you attempt to install the PowerConnect B-MLXe Series
management module in another Dell chassis or a management module intended for another Dell chassis in the
PowerConnect B-MLXe Series chassis, the chassis and module will not function properly.
provides the chassis slot numbers into which you must install the modules. Markings for the chassis slots
appear at the base of the slots.
Each PowerConnect B-MLXe Series chassis ships with the required switch fabric modules installed.
CAUTION
Use of a power screwdriver may twist the heads from the screws and is not recommended.
CAUTION
If you do not install a module in a slot, you must keep the slot blank in place. If you operate
the chassis with an uncovered slot, the system may overheat. Tighten the screws that secure
the slot blanks so that they remain in place when removing adjacent panels or modules.
CAUTION
If you are hot-swapping a module, allow a minimum of two seconds after a module (or power
supply or fan tray) has been removed before inserting a module in the same slot.
If you are installing a redundant management module, refer to the appropriate configuration guide for your product
for information about how the redundant module works, optional software configurations that you can perform, and
how to manage the redundancy feature.
TABLE 1
PowerConnect
B-MLXe
module installation
PowerConnect B-MLXe Series module
Chassis slot number
Management modules for 4-slot and 8-slot chassis
Management modules for 16-slot chassis
Active module – M1 (left)
Redundant module – M2 (right)
Active module – M1 (upper)
Redundant module – M2 (lower)
Interface modules for 4-slot chassis
Interface modules for 8-slot chassis
Interface modules for 16-slot chassis
1 – 4
1 – 8
1 – 16
Switch fabric modules for 4-slot and 8-slot chassis
Switch fabric modules for 16-slot chassis
SF1 – SF3
SF1 – SF4
Summary of Contents for PowerConnect B-MLXe Series
Page 2: ......
Page 34: ...32 PowerConnect B MLXe Getting Started Guide 53 1001995 01 ...
Page 51: ...PowerConnect B MLXe 入门指南 49 53 1001995 01 图 7 在 4 插槽机箱中安装模块 图 8 在 8 插槽机箱中安装模块 ...
Page 54: ...52 PowerConnect B MLXe 入门指南 53 1001995 01 图 11 为 8 插槽机箱安装电源设备 1 电源设备 1 ...
Page 65: ...53 1001995 01 2010 年 8 月 31 日 53 1001995 01 53 1001995 01 PowerConnect B MLXe 系列 使用說明指南 ...
Page 190: ...188 PowerConnect B MLXe Panduan Pengaktifan 53 1001995 01 ...
Page 224: ...222 Guida introduttiva a PowerConnect B MLXe 53 1001995 01 ...
Page 225: ...53 1001995 01 2010 年 8 月 31 日 53 1001995 01 53 1001995 01 PowerConnect B MLXe シリーズ はじめに ...
Page 244: ...242 PowerConnect B MLXe はじめに 53 1001995 01 図 11 8 スロットシャーシへの電源装置の取り付け 1 電源装置 1 ...
Page 256: ...254 PowerConnect B MLXe はじめに 53 1001995 01 ...
Page 257: ...53 1001995 01 2010 년 8 월 31 일 53 1001995 01 53 1001995 01 PowerConnect B MLXe 시리즈 시작 안내서 ...
Page 288: ...286 PowerConnect B MLXe 시작 안내서 53 1001995 01 ...
Page 320: ...318 PowerConnect B MLXe Guia de Noções Básicas 53 1001995 01 ...
Page 352: ...350 PowerConnect B MLXe Guía de introducción 53 1001995 01 ...
Page 353: ...382 עבודה תחילת מדריך PowerConnect B MLXe 53 1001995 01 ...