![Dell PowerConnect B-MLXe Series Getting Started Manual Download Page 13](http://html.mh-extra.com/html/dell/powerconnect-b-mlxe-series/powerconnect-b-mlxe-series_getting-started-manual_84533013.webp)
PowerConnect B-MLXe Getting Started Guide
11
53-1001995-01
CAUTION
For the DC input circuit to the system of a 16-slot chassis (1800W supply), make sure there
is a UL-Listed 60 amp circuit breaker, minimum -48VDC, double pole, on the input lugs to the
power supply. The input wiring for connection to the product should be copper wire, 6 AWG,
marked VW-1, and rated minimum 90
ο
C.
CAUTION
For the NEBS-compliant installation of 16-slot chassis with AC and DC systems, use a ground
wire of at least 6 American Wire Gauge (AWG). The ground wire should have an
agency-approved crimped connector (provided with the device) attached to one end, with the
other end attached to building ground. The connector must be crimped with the proper tool,
allowing it to be connected to both ground screws on the enclosure. Before crimping the
ground wire into the provided ground lug, ensure the bare copper wire has been cleaned and
antioxidant is applied to the bare wire.
Unpacking the PowerConnect B-MLXe Series
The PowerConnect B-MLXe Series ships with several items. Review the items listed under
on page 7, and verify the contents. If any items are missing, contact the place of purchase.
Remove your B-MLXe chassis from the shipping carton. Save the shipping carton and packing materials in case you
need to move or ship the chassis at a later time.
Installing a PowerConnect B-MLXe Series chassis in a rack
This section describes the following tasks:
•
“Preparing to mount a chassis in a rack”
•
“Removing shipping screws from the 4-slot and 8-slot chassis”
•
“Lifting guidelines for the 8-slot and 16-slot chassis”
•
“Mounting a chassis in a rack”
Preparing to mount a chassis in a rack
Because of the weight of a fully loaded PowerConnect B-MLXe Series chassis, Dell recommends mounting a chassis
in a rack before installing modules and AC power supplies if necessary.
In a standard 19-inch (EIA310-D) rack, you can install
•
Up to ten PowerConnect B-MLXe Series 4-slot chassis.
•
Up to six PowerConnect B-MLXe Series 8-slot chassis.
•
Up to three PowerConnect B-MLXe Series 16-slot chassis.
Summary of Contents for PowerConnect B-MLXe Series
Page 2: ......
Page 34: ...32 PowerConnect B MLXe Getting Started Guide 53 1001995 01 ...
Page 51: ...PowerConnect B MLXe 入门指南 49 53 1001995 01 图 7 在 4 插槽机箱中安装模块 图 8 在 8 插槽机箱中安装模块 ...
Page 54: ...52 PowerConnect B MLXe 入门指南 53 1001995 01 图 11 为 8 插槽机箱安装电源设备 1 电源设备 1 ...
Page 65: ...53 1001995 01 2010 年 8 月 31 日 53 1001995 01 53 1001995 01 PowerConnect B MLXe 系列 使用說明指南 ...
Page 190: ...188 PowerConnect B MLXe Panduan Pengaktifan 53 1001995 01 ...
Page 224: ...222 Guida introduttiva a PowerConnect B MLXe 53 1001995 01 ...
Page 225: ...53 1001995 01 2010 年 8 月 31 日 53 1001995 01 53 1001995 01 PowerConnect B MLXe シリーズ はじめに ...
Page 244: ...242 PowerConnect B MLXe はじめに 53 1001995 01 図 11 8 スロットシャーシへの電源装置の取り付け 1 電源装置 1 ...
Page 256: ...254 PowerConnect B MLXe はじめに 53 1001995 01 ...
Page 257: ...53 1001995 01 2010 년 8 월 31 일 53 1001995 01 53 1001995 01 PowerConnect B MLXe 시리즈 시작 안내서 ...
Page 288: ...286 PowerConnect B MLXe 시작 안내서 53 1001995 01 ...
Page 320: ...318 PowerConnect B MLXe Guia de Noções Básicas 53 1001995 01 ...
Page 352: ...350 PowerConnect B MLXe Guía de introducción 53 1001995 01 ...
Page 353: ...382 עבודה תחילת מדריך PowerConnect B MLXe 53 1001995 01 ...