Dell Networking

N1108T-ON/N1108P-ON/
N1124T-ON/N1124P-ON/

N1148T-ON/N1148P-ON

Switches

Getting Started Guide

Regulatory Models: E17W and E18W

Summary of Contents for N1108P-ON

Page 1: ...Dell Networking N1108T ON N1108P ON N1124T ON N1124P ON N1148T ON N1148P ON Switches Getting Started Guide Regulatory Models E17W and E18W ...

Page 2: ...attery in an extremely hot environment can result in leakage of flammable liquid gas or an explosion If a battery is subjected to extremely low air pressure it may result in leakage of flammable liquid gas or an explosion The device can only be used in a fixed location such as a lab or a machine room When you install the device ensure that the protective earthing connection of the socket outlet is...

Page 3: ...08P ON Installation 7 Rack Mounting an N1108T ON N1108P ON Switch 7 Installing in a Rack 7 3 N1124T ON N1124P ON N1148T ON N1148P ON Installation 9 Rack Mounting an N1124T ON N1124P ON N1148T ON N1148P ON Switch 9 Installing in a Rack 9 Wall Installation for N1108T ON and N1108P ON 10 Installing as a Free standing Switch 11 Stacking Multiple N1124T ON N1124P ON N1148T ON N1148P ON Switches 12 ...

Page 4: ...1100 ON Series Switch to a Power Source 15 AC and DC Power Connection 15 Booting the N1100 ON Series Switch 16 Performing the N1100 ON Series Initial Configuration 17 Enabling Remote Management 17 Initial Configuration Procedure 18 Example Session 19 Dell Easy Setup Wizard Console Example 20 Next Steps 24 5 NOM Information Mexico Only 26 ...

Page 5: ...itical infrastructure pre staging of the new release into a non critical portion of the network is recommended to verify network configuration and operation with the new DNOS version N1100 ON Series Hardware Overview This section contains information about device characteristics and modular hardware configurations for the Dell Networking N1100 ON Series switch Power Consumption for N1100 ON Series...

Page 6: ...0V 60Hz Main PSU 4 32A 472 64W 120V 60Hz Main PSU 3 95A 470 58W 220V 50Hz Main PSU 2 14A 459 37W 240V 50Hz Main PSU 1 97A 459 06W Marketing Model Name MMN Description Power Supply Unit PSU Regulatory Model Number RMN Regulatory TypeNumber RTN N1108T ON 10x1G 2x1G SFP Ports DPS 24GP E17W E17W001 N1108P ON 10x1G 2x1G SFP 2xPoE Ports DPS 80AP DPS 24GP E17W E17W001 N1124T ON 24x1G 4x10G SFP Ports DPS ...

Page 7: ...n a Rack WARNING Do not use rack mounting kits to suspend the switch from under a table or desk or attach it to a wall CAUTION Disconnect all cables from the switch before continuing Remove all self adhesive pads from the underside of the switch if they have been attached CAUTION When mounting multiple switches into a rack mount the switches from the bottom up 1 Secure the N1108T ON N1108P ON swit...

Page 8: ...rack ensuring that the rack mounting holes on the kit line up to the mounting holes in the rack 3 Secure the kit to the rack with either the rack bolts or cage nuts and cage nut bolts with washers depending on the kind of rack you have Fasten the bolts on the bottom before fastening the bolts on the top ...

Page 9: ...ot use rack mounting kits to suspend the switch from under a table or desk or attach it to a wall CAUTION Disconnect all cables from the switch before continuing Remove all self adhesive pads from the underside of the switch if they have been attached CAUTION When mounting multiple switches into a rack mount the switches from the bottom up 1 Place the supplied rack mounting bracket on one side of ...

Page 10: ...lts on the top CAUTION Make sure that the supplied rack bolts fit the pre threaded holes in the rack NOTE Make sure that the ventilation holes are not obstructed Wall Installation for N1108T ON and N1108P ON To mount the switch on a wall 1 Make sure that the mounting location meets the following requirements The surface of the wall must be capable of supporting the switch Allow at least two inches...

Page 11: ...7 On the marked locations drill the holes and place all plugs not provided in the holes 8 Secure the switch to the concrete wall or wood material with screws not provided Make sure that the ventilation holes are not obstructed Installing as a Free standing Switch NOTE Dell strongly recommends mounting the switch in a rack Install the switch on a flat surface if you are not installing it in a rack ...

Page 12: ... stack N1124T ON N1124P ON N1148T ON N1148P ON switches up to four switches high using 10G SFP ports on the front of the switch The ports must be configured to support stacking When multiple switches are connected together through the stack ports they operate as a single unit with up to 208 front panel ports The stack operates and is managed as a single entity Refer to the User Configuration Guide...

Page 13: ...d Configuring the N1100 ON Series Switch The following flow chart provides an overview of the steps you use to perform the initial configuration after the switch is unpacked and mounted Figure 1 5 Installation and Configuration Flow Chart ...

Page 14: ...port running VT100 terminal emulation software such as HyperTerminal and a USB driver The supplied USB cable with a type B USB connector for the console port and USB connector for the host PC Perform the following tasks to connect a terminal to the switch console port 1 Connect the USB type B connector on the supplied switch and connect the other end to a computer running VT100 terminal emulation ...

Page 15: ... Series models have one internal power supply The power receptacle is on the rear panel AC and DC Power Connection 1 Make sure that the switch console port is connected to a PC running a VT100 terminal emulator via the USB to USB Type B cable 2 Using a 5 foot 1 5 m standard power cable with safety ground connected connect the power cable to the AC main receptacle located on the rear panel The PoE ...

Page 16: ... critical problem the program flow stops If POST passes successfully valid firmware is loaded into RAM POST messages are displayed on the terminal and indicate test success or failure The boot process runs for approximately 60 seconds You can invoke the Boot menu after the first part of the POST is completed From the Boot menu you can perform configuration tasks such as resetting the system to fac...

Page 17: ... Before setting up the initial configuration of the switch obtain the following information from your network administrator The IP address to be assigned to the management interface The IP subnet mask for the network The IP address of the management interface default gateway These settings are necessary to allow the remote management of the switch through Telnet Telnet client or HTTP Web browser E...

Page 18: ...initial configuration by using the CLI refer to the CLI Reference Guide This Getting Started Guide shows how to use the Dell Easy Setup Wizard for initial switch configuration The wizard sets up the following configuration on the switch Establishes the initial privileged user account with a valid password The wizard configures one privileged user account during the setup Enables CLI login and HTTP...

Page 19: ... the wizard the switch is configured as follows SNMPv2 is enabled and the community string is set up as defined above SNMPv3 is disabled by default The admin user account is set up as defined A network management system is configured From the management station you can access the SNMP HTTP and CLI interfaces You may also choose to allow all IP addresses to access these management interfaces by cho...

Page 20: ... for providing recommendations to improve your IT infrastructure Dell SupportAssist also collects and stores machine diagnostic information which may include but is not limited to configuration information user supplied contact information names of data volumes IP addresses access control lists diagnostics performance information network configuration information host server configuration performa...

Page 21: ...lection transmission and or use of the Collected Data you may not download install or otherwise use SupportAssist ________AeroHive HiveManager NG EULA________________ This switch includes a feature that enables it to work with HiveManager an optional management suite by sending the switch s service tag number and IP Address to HiveManager to authenticate your entitlement to use HiveManager If you ...

Page 22: ...ddress and the community string or password that the particular management system uses to access the switch The wizard automatically assigns the highest access level Privilege Level 15 to this account You can use Dell Network Manager or other management interfaces to change this setting and to add additional management system information later For more information on adding management systems see ...

Page 23: ...tep 3 Next an IP address is set up on the VLAN 1 routing interface You can use the IP address to access the CLI Web interface or SNMP interface of the switch To access the switch through any Management Interface you can Set up the IP address for the Management Interface Set up the default gateway if IP address is manually configured on the routing interface Step 4 Would you like to set up the VLAN...

Page 24: ...ng Interface configuration please wait Next Steps After completing the initial configuration described in this section connect any of the front panel switch ports to a production network for in band remote management If you specified DHCP for the VLAN 1 management interface IP address the interface will acquire its IP address from a DHCP server on the network To discover the dynamically assigned I...

Page 25: ...VLANs and spanning tree protocol Use the Web based management interface or the CLI to configure the features your network requires For information about how to configure the switch features refer to the User Configuration Guide or CLI Reference Guide available on the support site dell com support ...

Page 26: ...11o Piso Col Lomas Altas 11950 México D F Ship to Dell Computer de México S A de C V al Cuidado de Kuehne Nagel de México S de R L Avenida Soles No 55 Col Peñon de los Baños 15520 México D F Supply voltage Dell Networking N1100 ON Series 100V 240 VAC Frequency Dell Networking N1100 ON Series 50 60 Hz Maximum steady state current consumption Dell Networking N1100 ON Series 110V circuit 0 43A 220V c...

Page 27: ...www dell com dell com support Printed in the U S A Impreso en los EE UU Imprimé aux U S A Impresso nos EUA ...