278
Using iDRAC6 Enterprise SM-CLP Command Line Interface
•
Display system properties
Server Power Management
Table 16-3 provides examples of using SM-CLP to perform power
management operations on a managed server.
Enter "
smclp
" to start the SM-CLP console.
SEL Management
Table 16-4 provides examples of using the SM-CLP to perform SEL-related
operations on the managed system.
MAP Target Navigation
Table 16-5 provides examples of using the
cd
verb to navigate the MAP. In all
examples, the initial default target is assumed to be /.
Table 16-3.
Server Power Management Operations
Operation
Syntax
Logging in to
iDRAC6 using the
SSH interface
>ssh 192.168.0.120
>login: root
>password:
Enter
"
smclp
"
to start the SM–CLP console.
Power down the
server
->stop /admin1/system1
system1 successfully stopped
Power up the server
from a powered-off
state
->start /admin1/system1
system1 successfully started
Reboot the server
->reset /admin1/system1
RESET successful for system1
Summary of Contents for IDRAC6
Page 38: ...38 iDRAC6 Enterprise Overview ...
Page 84: ...84 Configuring the Managed Server ...
Page 120: ...120 Configuring iDRAC6 Enterprise Using the Web Interface ...
Page 160: ...160 Using iDRAC6 With Microsoft Active Directory ...
Page 166: ...166 Configuring Smart Card Authentication ...
Page 222: ...222 Using GUI Console Redirection ...
Page 228: ...228 Configuring the vFlash Media Card for Use With iDRAC6 ...
Page 270: ...270 Using the RACADM Command Line Interface ...
Page 308: ...308 Using iDRAC6 Configuration Utility ...
Page 334: ...334 Recovering and Troubleshooting the Managed System ...
Page 382: ...382 RACADM Subcommand Overview ...
Page 452: ...452 iDRAC6 Enterprise Property Database Group and Object Definitions ...
Page 462: ...462 Glossary ...