AX100-Series - Installing a Fibre Channel Storage System with a Direct Connection to a Solaris Server
45
Initializing the Storage System
Run the Navisphere Storage System Initialization Utility
1. Before continuing, make sure that the storage system is powered
up completely:
• The
Fault lights on each SP must be off and the Power light
must be on. These lights are on the back of the storage system
(Figure 16).
• The amber system Fault light visible from the front of the
storage system must be off (Figure 16).
Figure 16
S
torage-System Lights (LEDs)
2. As superuser (root), start the Navisphere Storage System
Initialization Utility:
cd /opt/Navisphere/bin
./naviinittool
3. Read the license agreement and enter
y
to accept it.
The utility automatically scans the subnet for AX100-Series
storage systems. When this storage-system discovery operation is
complete, the utility lists, by hardware serial number, all
FE 0
FE 1
FE 0
FE 1
Power
SP A Boot/Fault
Power Supply A Fault
Power Supply B Fault
SP B Boot/Fault
EMC2928d
SP B
SP A
Rear Lights (AX100)
Fault
Disk Activity
EMC2934
Power
Front Lights