28
About Your System
E1810 Hard drive ##
fault. Review
& clear SEL.
The specified hard drive
has experienced a fault.
See "Troubleshooting a
Hard Drive" on page 152.
E1812 Hard drive ##
removed. Check
drive.
The specified hard
drive has been removed
from the system.
Information only.
E1920 iDRAC6 Upgrade
Failed.
Optional iDRAC6
upgrade has failed.
See "Troubleshooting
Expansion Cards" on
page 155.
E1A14 SAS cable A
failure. Check
connection.
SAS cable A is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 169.
E1A15 SAS cable B
failure. Check
connection.
SAS cable B is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 169.
E1A1D Control panel
USB cable not
detected.
Check cable.
USB cable to the control
panel is missing or bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 169.
E2010 Memory not
detected.
Inspect DIMMs.
No memory was detected
in the system.
Install memory or reseat
memory modules. See
"Installing Memory
Modules" on page 115 or
"Troubleshooting System
Memory" on page 148.
Table 1-1. LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 28 Wednesday, December 22, 2010 2:13 PM
Summary of Contents for DX6000G
Page 1: ...Dell DX6000G Systems Hardware Owner s Manual ...
Page 8: ...8 Contents ...
Page 54: ...54 About Your System ...
Page 76: ...76 Using the System Setup Program and UEFI Boot Manager ...
Page 156: ...158 Troubleshooting Your System ...
Page 166: ...168 Jumpers and Connectors ...
Page 168: ...170 Getting Help ...