![Dell 1907FPf Service Manual Download Page 16](http://html.mh-extra.com/html/dell/1907fpf/1907fpf_service-manual_83343016.webp)
Service Manual
15
81
RX0-
I
Do not connect.
82
AVDD_DVI_33
P
Analog VDD (3.3V) for DVI input. Reserved for gm2621 and
gm2621; Do not connect.
83
RXC+
I
Do not connect.
84
RXC-
I
Do not connect.
85
AVSS_DVI
G
Analog GND for DVI input. Reserved for gm2621 and gm2621;
Do not connect.
86
AVDD_DVI_18
P
Analog VDD (1.8V) for DVI input.
Must be bypassed with external capacitor(s) to AVSS_DVI.
Reserved for gm2621 and gm2621; Do not connect.
87
CVDD_18
P
Core VDD connect to digital 1.8V
88
CRVSS
G
Chip digital ground
89
HSYNC
I
ADC input horizontal sync or composite sync input.
90
VSYNC
I
ADC input vertical sync
91
RVDD_33V
P
Digital Output VDD. Connect to digital 3.3V
92
AVDD_ADC_33
I
1.8V for gmZAN3SL core
93
BLUE+
I
Positive analog input for Blue channel
94
BLUE-
I
Negative analog input for Blue channel
95
AVSS_ADC
G
Analog ground for ADC
96
GREEN+
I
Positive analog input for Green channel
97
GREEN-
I
Negative analog input for Green channel
98
AVSS_ADC
G
Analog ground for ADC
99
RED+
I
Positive analog input for Red channel
100 RED-
I
Negative analog input for Red channel
101 AVDD_ADC_33
P
Analog power (3.3V) for ADC. Must be bypassed with capacitor
to AVSS_ADC pin.
102 AVSS_ADC
G
Analog ground for ADC
103 AVSS_ADC
G
Analog ground for ADC
104 AVDD_ADC_18
P
Analog power (1.8V) for ADC. Must be bypassed with capacitor
to AVSS_ADC pin.
105 VBUFC_RPLL
O
Reserved; Do not connect
106 VDD_RPLL_18
P
Digital 1.8V Power for PLL
107 VSS_RPLL
G
Ground for PLL
108 XTAL
O
Connect to 14.3MHz crystal. Should be bypassed with capacitor
to AVDD_RPLL_33.
109 TCLK
I
Connect to 14.3MHz crystal. Should be bypassed with capacitor
to AVDD_RPLL_33.
110 AVDD_RPLL_33
P
Analog power (3.3V) for PLL
111 RESETn
I/O Bypass with 0.01uF capacitor GND
112 LBADC_VSS
G
Ground for general-purpose LBADC
113 LBADC_IN3
I
Ground-purpose LBADC input 3.
114 LBADC_IN2
I
Ground-purpose LBADC input 2.
115 LBADC_IN1
I
Ground-purpose LBADC input 1.
116 LBADC_VDD_33
P
3.3V supply for general-purpose LBADC.
117 CRVSS
G
Chip digital ground
118 CVDD_18
P
Core VDD connect to digital 1.8V
119 PWM0/GPO_5
I/O PWM0 output or optional general-purpose output GPO_5.
Also used for bootstrap control
120 GPIO_8
I/O General-purpose input/output 8
121 GPIO_9
I/O General-purpose input/output 9
122 GPIO_10
I/O General-purpose input/output 10
123 GPIO_11
I/O General-purpose input/output 11
124 GPIO_12
I/O General-purpose input/output 12
Summary of Contents for 1907FPf
Page 1: ...Service Manual 0 Service Manual LCD Monitor 1907FPf ...
Page 55: ...Service Manual 54 ...
Page 56: ...Service Manual 55 Attachment 2 Schematic ...
Page 57: ...Service Manual 56 ...
Page 58: ...Service Manual 57 ...
Page 59: ...Service Manual 58 ...
Page 60: ...Service Manual 59 ...
Page 61: ...Service Manual 60 ...
Page 62: ...Service Manual 61 ...
Page 63: ...Service Manual 62 ...
Page 64: ...Service Manual 63 ...
Page 65: ...Service Manual 64 ...
Page 66: ...Service Manual 65 ...
Page 67: ...Service Manual 66 ...
Page 68: ...Service Manual 67 ...
Page 69: ...Service Manual 68 ...
Page 70: ...Service Manual 69 ...
Page 71: ...Service Manual 70 Attachment 3 PCB Layout Interface Board ...
Page 72: ...Service Manual 71 ...
Page 73: ...Service Manual 72 Power Inverter Board ...
Page 74: ...Service Manual 73 Keypad Board ...
Page 75: ...Service Manual 74 ...
Page 76: ...Service Manual 75 USB Control Board ...
Page 77: ...Service Manual 76 Inverter Control Board ...
Page 78: ...Service Manual 77 Power Control Board ...
Page 79: ...Service Manual 78 ...
Page 80: ...Service Manual 79 ...