Fault LED (Amber)
Status/description*
Any links down: On
Drive link (PHY lane) down
On
Fault (leftover/failed/locked-out)
Off
Available
Off
Storage system: Initializing
Off
Storage system: Fault-tolerant
Off
Storage system: Degraded (non-critical)
Blinking: 3s on/1s off
Storage system: Degraded (critical)
Off
Storage system: Quarantined
Blinking: 3s on/1s off
Storage system: Offline (dequarantined)
Off
Storage system: Reconstruction
Off
Processing I/O (whether from host or internal activity)
*If multiple conditions occur simultaneously, the LED state will behave as indicated by the condition listed earliest in the table, as rows are
read from top to bottom.
Each DDIC has a single Drive Fault LED. A disk drive fault is indicated if the Drive Fault LED is lit amber. In the event of a disk failure, follow
the procedure in
.
IOM LEDs
NOTE:
IOM CRUs are common to the 2U and 5U84 enclosures.
•
For information about controller module LEDs see
12 Gb/s controller module LEDs
.
•
For information about expansion module LEDs see
.
Troubleshooting 2U enclosures
The following sections describe common problems that can occur with your enclosure system, and some possible solutions. For all of the
problems listed in
, the Module Fault LED on the Ops panel will light amber to indicate a fault. All alarms also
report using SES.
Table 20. 2U alarm conditions
Status
Severity
Alarm
PCM alert - loss of DC power from a single PCM
Fault – loss of redundancy
S1
PCM fan fail
Fault – loss of redundancy
S1
SBB module detected PCM fault
Fault
S1
PCM removed
Configuration error
None
Enclosure configuration error (VPD)
Fault – critical
S1
Low warning temperature alert
Warning
S1
High warning temperature alert
Warning
S1
Troubleshooting and problem solving
39