NOTE:
SAS HBAs have two ports. The World Wide Port Name (WWPN) for port 0 ends in zero and the WWPN for
port 1 ends in one.
Register the host and create and map volumes
Perform the following steps to register a host, create volumes, and map volumes:
1. Log in to the ME Storage Manager.
2. Access the Host Setup wizard by doing one of the following:
•
From the Welcome screen, click
Host Setup
.
•
From the Home topic, click
Action
>
Host Setup
.
3. Confirm that you have met the listed prerequisites, then click
Next
.
4. Enter a hostname.
5. Select the SAS initiators for the host you are configuring, then click
Next
.
Use the information from step 5 of the
Attach SAS hosts to the storage system
procedure to identify the correct SAS initiators.
6. Group hosts together with other hosts.
a) For cluster configurations, use the “Host groups” setting to group hosts in a cluster.
•
If this host is the first host in the cluster, select
Create a new host group
, then provide a name and click
Next
.
•
If this host is being added to a host group that exists, select
Add to existing host group
. Select the group from the drop-
down list, then click
Next
.
b) For stand-alone hosts, select the
Do not group this host
option, then click
Next
.
7. On the Attach volumes page, use the options to change the volume name and size, select the pool for the volume, and add or delete
volumes. Click
Next
.
NOTE:
Dell EMC recommends that you update the volume name with the hostname to better identify the volumes.
8. On the Summary page, review the changes, then click
Configure Host
.
•
Click
Yes
to return to the Select Host page of the wizard, or choose
No
to close the wizard.
•
Click
Previous
to go back and change the settings.
Enable multipathing on SAS volumes
Perform the following steps to enable multipathing on SAS volumes:
1. Log in to the VMware vCenter Server, then click the ESXi host.
2. On the Configure tab, select
Storage
>
Storage Adapters
.
3. Select the SAS HBA and click
Rescan Storage
.
The
Rescan Storage
dialog box opens.
4. Click
OK
.
5. Select the Dell EMC disk that was added to the ESXi host in
Register the host and create and map volumes
.
6. Click the
Properties
tab that is located below the selected disk.
7. Click
Edit Multipathing
.
The
Edit Multpathing Policies
dialog box opens.
8. Select a multipathing policy for the volume from the
Path selection policy
drop-down list and click
OK
.
NOTE:
The VMware multipathing policy defaults to Most Recently Used (VMware). Use the default policy for a host
with one SAS HBA that has a single path to both controllers. If the host has two SAS HBAs (for example, the host
has two paths to each controller), Dell EMC recommends that you change the multipathing policy to Round Robin
(VMware).
9. Repeat steps 5–8 for each SAS volume that is attached to the ESXi host.
VMware volume rescan and datastore creation
Perform the following steps to rescan volumes and create datastores:
1. Log in to the VMware vCenter Server, then click the ESXi host.
2. On the Configure tab, select
Storage
>
Storage Adapters
.
3. Select the SAS HBA and click
Rescan Storage
.
The
Rescan Storage
dialog box opens.
Perform host setup
57