Configuring the switches with two different IP address ranges/subnets enables high availability.
Configure the VMware ESXi VMkernel
Perform the following steps to configure the VMware ESXi VMkernel:
1. From the VMWare VSphere web client, click
Configure
>
Networking
>
Physical adapters
.
2. Locate and document the device name for the NICs used for iSCSI traffic.
3. Click the VMkernel adapters, then click the plus (+) icon to create a VMkernel adapter.
4. On the Select Connection Type page, select
VMkernel Network Adapter
>
Next
.
5. On the Select Target Device page, select
New standard switch
>
Next
.
6. On the Create Standard Switch page, click the plus (+) icon, then select
vmnic
>
OK
to connect to the subnet defined in step 4 of
the “Attach hosts to the storage system” procedure.
7. Click
Next
.
8. Provide a network label, then update the port properties.
9. On the IPv4 settings page, select
Static IP
and assign an IP using your planning worksheet.
10. Click
Next
.
11. On the Ready to complete page, review the settings and then click
Finish
.
12. Repeat steps 1–11 for each NIC to use for iSCSI traffic.
NOTE:
If you are using jumbo frames, they must be enabled and configured on all devices in the data path, adapter
ports, switches, and storage system.
Configure the software iSCSI Adapter on the ESXi host
Perform the following steps to configure a software iSCSI adapter on the ESXI host:
NOTE:
If you plan to use VMware ESXi with 10GBase-T controllers, you must perform
one
of the following tasks:
•
Update the controller firmware to the latest version posted on
before connecting the ESXi host to the ME4 Series
storage system.
OR
•
Run the following ESX CLI command on every ESXi host before connecting it to the ME4 Series storage system:
esxcli system settings advanced set --int-value 0 -option /VMFS3 /HardwareAcceleratedLocking
1. Log in to the VMware vCenter Server.
2. On the
Configure
tab, select
Storage
>
Storage Adapters
.
3. Click the plus (+) icon, then select
software iSCSI adapter
>
OK
. The adapter is added to the list of available storage adapters.
4. Select the newly added iSCSI adapter, then click
Targets
>
Add
.
5. Enter the iSCSI IP address that is assigned to the iSCSI host port of storage controller A, then click
OK
.
6. Repeat steps 4-5 for the iSCSI host port of storage controller B.
7. If multiple VMkernels are used on the same subnet, configure the network port binding:
a) On the software iSCSI adapter, click the
Network Port Binding
tab, then click the plus (+) icon to add the virtual network port
to bind with the iSCSI adapter.
NOTE:
This step is required to establish a link between the iSCSI Adapter and the Vmkernel adapters that are
created in the
Configure the VMware ESXi VMkernel
procedure.
If each of the VMkernels used for iSCSI are on separate subnets, skip this step.
b) Select the VMKernel adapters that are created in the
Configure the VMware ESXi VMkernel
procedure, then click
OK
.
c) Select
Rescan of storage adapters
.
Register the host and create and map volumes
Perform the following steps to register the host, create volumes, and map volumes:
1. Log in to the Storage Manager.
2. Access the Host Setup wizard by doing one of the following:
•
From the Welcome screen, click
Host Setup
.
Perform host setup
55