connectors with corresponding LEDs. These LEDs indicate the link and activity of each
SAS connector for input and output to devices.
Note
Disconnect power to the DAE when changing the ICM.
Table 38 ICM bus status LEDs
LED
Color
State
Description
Power fault
Green
On
Power on
—
Off
Power off
Power on
Amber
On
Fault
—
Off
No fault or power off
The ICM supports the following I/O ports on the rear:
l
Four 6 Gb/s PCI Gen2 SAS ports
l
One management (RJ-12) connector to the SPS (field service diagnostics only)
l
One USB connector
l
One 6 Gb/s SAS x8 ports
It supports four 6 Gb/s SAS x8 ports on the rear of the ICM (two inputs and two
outputs, one used in Gen1 hardware and two used in Gen2 hardware). This port
provides an interface for SAS and NL-SAS drives in the DAE.
Table 39 ICM 6 Gb/s port LEDs
LED
Color
State
Description
Link/Activity
Blue
On
Indicates a 4x or 8x connection with all lanes
running at 6 Gb/s.
Green
On
Indicates that a wide port width other than 4x
or 8x has been established or one or more
lanes is not running at full speed or
disconnected.
—
Off
Not connected.
Disk Drives
64
D- and U-Series
Hardware Guide
Summary of Contents for ECS D Series
Page 1: ...Dell EMC Elastic Cloud Storage ECS D and U Series Hardware Guide 302 003 477 09 ...
Page 8: ...TABLES 8 D and U Series Hardware Guide ...
Page 25: ...CHAPTER 2 Servers l ECS Appliance servers 26 l Rack and node host names 30 Servers 25 ...
Page 32: ...Servers 32 D and U Series Hardware Guide ...
Page 33: ...CHAPTER 3 Switches l ECS Appliance switches 34 Switches 33 ...
Page 44: ...Switches 44 D and U Series Hardware Guide ...
Page 70: ...Third Party Rack Requirements 70 D and U Series Hardware Guide ...
Page 88: ...Power Cabling 88 D and U Series Hardware Guide ...
Page 89: ...CHAPTER 7 SAS Cabling l U Series SAS cabling 90 l D Series SAS cabling 93 SAS Cabling 89 ...
Page 99: ...Figure 61 U Series and D Series network cabling Network Cabling Network cabling 99 ...