Table 4 U-Series (Gen2) configurations
Model number
Nodes
DAEs
Disks in DAE
Storage capacity
Switches
(8 TB disks) (12 TB disks)
U400 (minimum
configuration)
4
4
10
320 TB
480 TB
One private and two
public
U400-E
5
5
10
400 TB
600 TB
One private and two
public
U480-E
6
6
10
480 TB
720 TB
One private and two
public
U400-T
8
8
10
640 TB
960 TB
One private and two
public
U2000
8
8
30
1.92 PB
2.88 PB
One private and two
public
U2800
8
8
45
2.88 PB
4.32 PB
One private and two
public
U4000 (maximum
configuration)
8
8
60
3.84 PB
5.76 PB
One private and two
public
Note
Five-node configurations are the smallest configuration that can tolerate a node
failure and still maintain the EC protection scheme. A four-node configuration that
suffers a node failure changes to a simple data mirroring protection scheme. Five-
node configurations are the recommended minimum configuration.
U-Series (Gen2) upgrade paths
U-Series Gen2 upgrades can be applied flexibly to eligible configurations. Multiple
upgrades can be applied in one service call.
Upgrade rules for an appliance with all 8 TB or 12 TB disks (upgrade will not include
mixed disk capacities in the rack):
l
The minimum number of disks in a DAE is 10.
l
Disk Upgrade Kits are available in 5 or 10 disk increments.
l
All DAEs in the appliance must have the same number of disks in increments of 5
(10, 15, 20, and so on, up to 60) with NO empty slots between disks.
l
Upgrades are flexible, meaning you can upgrade to any disk level even if that level
does not correspond to a named model. For example, you can upgrade the original
appliance to have 35 disks per DAE even though this configuration does not have
an official label like the U2000 (30 disks per DAE) or the U2800 (45 disks per
DAE).
l
To upgrade a half-rack configuration to a full-rack configuration, you must order
the
1 Server Chassis containing 4 nodes, 4 DAEs with 10, 20,
30, 45 or 60 Upgrade Kit
. To achieve any configuration between 10, 20, 30
45 or 60 disks, add 5 or 10 disk upgrade kits in the required quantity to match the
disk quantities per DAE in nodes 1-4.
l
All empty drive slots must be filled with a disk filler.
Hardware Components and Configurations
16
D- and U-Series
Hardware Guide
Summary of Contents for ECS D Series
Page 1: ...Dell EMC Elastic Cloud Storage ECS D and U Series Hardware Guide 302 003 477 09 ...
Page 8: ...TABLES 8 D and U Series Hardware Guide ...
Page 25: ...CHAPTER 2 Servers l ECS Appliance servers 26 l Rack and node host names 30 Servers 25 ...
Page 32: ...Servers 32 D and U Series Hardware Guide ...
Page 33: ...CHAPTER 3 Switches l ECS Appliance switches 34 Switches 33 ...
Page 44: ...Switches 44 D and U Series Hardware Guide ...
Page 70: ...Third Party Rack Requirements 70 D and U Series Hardware Guide ...
Page 88: ...Power Cabling 88 D and U Series Hardware Guide ...
Page 89: ...CHAPTER 7 SAS Cabling l U Series SAS cabling 90 l D Series SAS cabling 93 SAS Cabling 89 ...
Page 99: ...Figure 61 U Series and D Series network cabling Network Cabling Network cabling 99 ...