![Dell EMC BOSS-S1 User Manual Download Page 24](http://html1.mh-extra.com/html/dell-emc/boss-s1/boss-s1_user-manual_2468347024.webp)
Troubleshooting
To get help with your Dell BOSS-S1 card, you can contact your Dell Technical Service representative or see
Dell.com/support
.
Topics:
•
BOSS-S1 CLI displays No Adapter Found error in Linux
•
LC log displays fan unavailability error
•
Updating BOSS-S1 controller firmware using iDRAC/LC fails
•
Physical disk size as zero in iDRAC
•
Character limitation while naming a virtual disk
•
•
Physical disk not visible to operating system
•
Virtual disk not visible to operating system
•
•
•
•
Unable to boot to M.2 drive installed in slot 1
•
CLI reports unsupported features
•
Failure to install ESXi on RAID 1
BOSS-S1 CLI displays No Adapter Found error in Linux
Issue:
BOSS-S1 CLI displays
No Adapter Found
error message in the Linux operating system.
Probable Cause:
Using BOSS-S1 CLI, when you run the CLI commands using non-administrative user privileges, the error No
Adapter found is displayed.
Corrective Action:
Use root/sudo administrator privilege while you run the CLI commands.
LC log displays fan unavailability error
Issue:
LC log displays
The BOSS-S1 device does not have a fan installed in it
error message.
Probable Cause:
Currently there is no fan requirement for BOSS-S1, which might be required in future based on M.2 thermal
requirement.
Corrective Action:
No action required. This error message can be ignored.
Updating BOSS-S1 controller firmware using
iDRAC/LC fails
Issue:
Updating firmware on a BOSS-S1 controller from versions A00 to A01 using iDRAC/LC fails.