User’s
Guide
deliberant
Page
64
Appendix
A)
Resetting
Device
to
Factory
Defaults
Device has the capability of being reset to defaults by pinging the device with a certain packet size
when the radio is booting. During the startup of the device, when the drivers of the Ethernet interfaces
are loaded, the discovery daemon is started. The daemon suspends startup process for 3 seconds
and waits for ICMP "
echo request
" packet of length 369 bytes. If the packet received, the
discoveryd resets the device to default configuration.
It is recommended to connect PC to the device via switch, as depending on PC OS
settings, the ARP table might be flushed during wired link status change (connecting the
device that will be reset).
Steps to reset to default settings:
Step 1.
Power off the APC device.
Step 2.
Obtain the device MAC address.
Step 3.
Connect a PC to the same physical subnet as the device.
Step 4.
Execute 'arp -s' command to assign the IP address (IP address should be from the
same subnet as PC) to the device MAC address:
arp -s <IP address to assign> <device MAC address>
Note that syntax of MAC address differs depending on OS:
Linux OS: AA:BB:CC:DD:EE:FF
Windows OS: AA
-
BB
-
CC
-
DD
-
EE
-
FF
Step 5.
Start ping the device:
For Linux users:
ping <IP address> -s 369
For Windows users:
ping <IP address> -l 369 -t -w 0.2
Step 6.
Power up APC device and wait about 30sec or more (depending on device hardware).
Step 7.
Stop pinging the device, and let the device boot as usual. The device should start up
with factory default settings.