Electrical Service
DANGER
Check all wiring connections, including factory terminals,
before operation. Connections can become loose during
shipment and installation.
n
Warning
This appliance must be grounded and all field wiring must
conform to all applicable local and national codes. Refer
to rating plate for proper voltage. It is the responsibility of
the end user to provide the disconnect means to satisfy
the authority having jurisdiction.
• Plug units with R290 refrigerant into a receptacle that is a
minimum of 14” (36cm) above the floor.
• All electrical work, including wire routing and grounding,
must conform to local, state and national electrical codes.
• The equipment must be grounded.
• A separate fuse/circuit breaker must be provided for each
unit.
• The maximum allowable voltage variation is ±10% of the
rated voltage at equipment start-up (when the electrical
load is highest).
• Check all green ground screws, cables and wire
connections to verify they are tight before start-up.
GROUND FAULT CIRCUIT INTERRUPTER
Ground Fault Circuit Interrupter (GFCI/GFI) protection is a
system that shuts down the electric circuit (opens it) when it
senses an unexpected loss of power, presumably to ground.
Welbilt does not recommend the use of GFCI/GFI circuit
protection to energize our equipment. If code requires the
use of a GFCI/GFI then you must follow the local code. The
circuit must be dedicated, sized properly and there must
be a panel GFCI/GFI breaker. We do not recommend the
use of GFCI/GFI outlets to energize our equipment as they
are known for more intermittent nuisance trips than panel
breakers.
ELECTRICAL SPECIFICATION CHART
Maximum 10ft (3m) cord with plug.
Model
Amps
V, Hz, Ph
H.P.
Nema Plug
Reach-In Dual Temperature
GADBR1P-SH
GADTR1P-SH
5.8
115, 60, 1
Ref. 0.20
Frzr. 0.315
5-15P
GADFL2P-S
GADRL2P-S
11.4
115, 60, 1
Ref. 0.22
Frzr. 0.55
5-15P
Reach-In Freezer
GAF1P-S(H)
7.2
115, 60, 1
0.55
5-15P
GAF2P-S(H)
10.0
115, 60, 1
0.68
5-15P
GAF3P-S(H)
14.7
115, 60, 1
(2X)0.55
5-20P
Pass-Thru Freezer
GAFPT1P-S(H)
10.0
115, 60, 1
0.55
5-15P
GAFPT2P-S(H)
14.6
115, 60, 1
(2X)0.55
5-20P
Roll-In Freezer
GAFRI1P-S
10.0
115, 60, 1
0.68
5-15P
GAFRI2P-S
14.6
115, 60, 1
(2X)0.55
5-20P
Reach-In Heated
GAH1-G(H)
6.0
208-240, 60, 1
NA
6-20P
GAH1-S(H)
6.0
GAH2-G(H)
10.5
208-240, 60, 1
NA
6-20P
GAH2-S(H)
10.5
Pass-Thru Heated
GAHPT1-G(H)
6.0
208-240, 60, 1
NA
6-20P
GAHPT1-S(H)
6.0
GAHPT2-G(H)
10.5
208-240, 60, 1
NA
6-20P
GAHPT2-S(H)
10.5
Roll-In Heated
GAHRI1-G
6.0
208-240, 60, 1
NA
6-20P
GAHRI1-S
6.0
GAHRI2-G
10.5
208-240, 60, 1
NA
6-20P
GAHRI2-S
10.5
Roll-Thru Heated
GAHRT1-S
6.0
208-240, 60, 1
NA
6-20P
GAHRT2-S
10.5
208-240, 60, 1
NA
6-20P
Narrow Reach-In Refrigerator
GAR1NP-G(H)
4.2
115, 60, 1
0.22
5-15P
GAR1NP-S(H)
4.2
GAR2NP-G(H)
6.0
115, 60, 1
0.33
5-15P
GAR2NP-S(H)
6.0
Reach-In Refrigerator
GAR1P-G(H)
4.2
115, 60, 1
0.22
5-15P
GAR1P-S(H)
4.2
GAR2P-G(H)
6.0
115, 60, 1
0.33
5-15P
GAR2P-GL
6.0
GAR2P-S(H)
6.0
GAR3P-G(H)
6.5
115, 60, 1
0.355
5-15P
GAR3P-S(H)
6.5
Reach-In Fishfile
GARFF1P-D
4.2
115, 60, 1
0.22
5-15P
Pass-Thru Refrigerator
GARPT1P-G(H)
4.5
115, 60, 1
0.22
5-15P
GARPT1P-S(H)
4.5
GARPT2P-G(H)
6.2
115, 60, 1
0.33
5-15P
GARPT2P-S(H)
6.2
Summary of Contents for Specification Line GA Series
Page 6: ...6 Part Number GA_SM 08 18 General Information Section 1 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 20: ...20 Part Number GA_SM 08 18 Installation Section 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 36: ...36 Part Number GA_SM 08 18 Troubleshooting Section 5 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 48: ...48 Part Number GA_SM 08 18 Control Section 6 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 94: ...94 Part Number GA_SM 08 18 Refrigeration Section 8 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 102: ...102 Part Number GA_SM 08 18 Diagrams Section 9 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 103: ......