78
Part Number GA_SM 08/18
Refrigeration
Section 8
2 SECTION REACH-IN FREEZER
100°F (38°C) Ambient / 32°F (0°C) Box Temperature
Evaporator
Inlet
Evaporator
Outlet
Suction
Line
Compressor
Top
Compressor
Bottom
Condenser
Inlet
Condenser
Outlet
-17°F
-12°F
35°F
152°F
139°F
165°F
109°F
-27°C
-24°C
2°C
67°C
59°C
74°C
43°C
-17°F
-12°F
104°F
152°F
165°F
35°F
139°F
109°F