Air Curtain Refrigerator Service and Installation Manual
5
For customer service, call (800) 733-8829 or (800) 733-8948, Fax (989) 773-3210, www.delfield.com
Specifications
Model ACR-26S
V/Hz/Ph
Amps
Volume 18"x26" Tray
Capacity
H.P.
404A
Charge
BTU/Hr
Door Closed
BTU/Hr
System Cap.
Ship
Weight
NEMA
Plug
115/60/1
14.0
12.5ft3
10
1/2
32oz
504
3300
592lbs/
269kg
5-20P
Location
The ACR-26S is intended for indoor use only. Be sure the
location chosen has a floor strong enough to support the
total weight of the cabinet and contents. Reinforce the floor if
necessary to provide for maximum loading.
Avoid placing unit under air conditioning vents or other ventilation
fans that may affect the air curtain when door is open.
Leveling
A level cabinet looks better and will perform better because the
doors will line up with the door frames properly, the cabinet will
not be subject to undue strain, and the contents of the cabinet will
not move around on the shelves. Use a level to make sure the unit
is level from front to back and side to side.
Stabilizing
The ACR-26S is supplied with casters for your convenience,
ease of cleaning underneath and for mobility. Two locking
casters allow you to stabilize the unit if you are loading or
unloading product.
Electrical connection
Refer to the amperage data shown in this manual, the serial tag
and your local code or the National Electrical Code for proper
wire sizes. All case wiring is labeled with the required voltage-
be sure it is connected to the proper power source. A protected
circuit of the correct voltage and amperage must be run for
connection of the line cord or permanent connection to the unit.
Reversing the door hinging
The following steps will allow you to reverse the side the door
hinges on.
1. Open the door to 180° open position.
2. Lift up door and remove door from hinges in fully open
position.
3. Remove pins from hinges.
4. Remove both hinges and relocate on the opposite side.
Tighten hinges.
5. Unscrew the lock stop tab from the top of door and mount
to the bottom in the holes provided.
6. Invert the door and mount it into the hinges in the fully
open position.
Installation
When the door is open, Delfield’s patented air curtain design
directs cold air across the cabinet opening, keeping hot air out
and cold air in for two hours at a time. The unit will maintain
a maximum of 45°F box temperature at 70°F ambient with the
door open during peak production times, quickly returning to a
normal 36°F. With the door closed, a maximum 40°F at 100°F
ambient is maintained (normal operation) while running only
15% in an 85° room.
Don’t pack the interior of the refrigerator so full that air cannot
circulate. When operating open, keep shelves filled with trays
and trays pushed all the way in so that they do not disrupt the
air curtain air flow.
Open the ACR’s door completely and the magnetic strip built in
to the frame allows the door to remain open while loading or
unloading.
The power switch should be turned to the OFF position and the
power cord disconnected whenever performing maintenance
functions or cleaning the refrigerated cabinet area.
Operation