Receiving and Inspecting the Equipment

Receiving And Inspecting . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Serial Number Location  . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Warranty Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Regulatory Certifications. . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
ERC2 Control Instructions
 Programming. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-10
 

Error Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Wiring Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Replacement Parts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Notes  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14-15

Even though most equipment is shipped crated, care should be 

taken during unloading so the equipment is not damaged while 

being moved into the building.

1.  Visually inspect the exterior of the package an skid or 

container. Any damage should be noted and reported to the 

delivering carrier immediately.

2.  If damaged, open and inspect the contents with the carrier.
3.  In the event that the exterior is not damaged, yet upon 

opening, there is concealed damage to the equipment notify 

the carrier. Notification should be made verbally as well as in 

written form.

4.  Request an inspection of the concealed equipment. This 

should be done within 10 days from receipt of the equipment.

5.  Check the lower portion of the unit to be sure legs or casters 

are not bent.

6.  Also open the compressor compartment housing and visually 

inspect the refrigeration package. Be sure lines are secure 

and base is still intact.

7.  Freight carriers can supply the necessary forms upon 

request.

8.  Retain all crating material until an inspection has been made 

or waived.

Uncrating the Equipment

First cut and remove the banding from around the crate. Remove 

the front of the crate material, use of some tools will be required. 

If the unit is on legs remove the top of the crate as well and lift 

the unit off the skid. If the unit is on casters it can be "rolled" off 

the skid.

Summary of Contents for ACR-26S

Page 1: ...d Installation Manual Please read this manual completely before attempting to install this equipment Notify carrier of damage Inspect all components immediately February 2013 Important Information Rea...

Page 2: ...e Is Not Intended For Use By Persons Who Lack Experience Or Knowledge Unless They Have Been Given Supervision Or Instruction Concerning Use Of The Appliance By A Person Responsible For Their Safety WA...

Page 3: ...he contents with the carrier 3 In the event that the exterior is not damaged yet upon opening there is concealed damage to the equipment notify the carrier Notification should be made verbally as well...

Page 4: ...g for parts or service A complete list of authorized Delfield parts depots can be found on www delfield com 2013 The Delfield Company All rights reserved Reproduction without written permission is pro...

Page 5: ...ge be sure it is connected to the proper power source A protected circuit of the correct voltage and amperage must be run for connection of the line cord or permanent connection to the unit Reversing...

Page 6: ...ry thoroughly Routine cleaning of stainless steel can be done with soap and water Extreme stains or grease should be cleaned with a non abrasive cleaner and plastic scrub pad Always rub with the grain...

Page 7: ...rs Three buttons are used for the programming SET UP and DOWN Fig 2 Display Lay out Follow these steps to change time of day and setpoint temperature First Level Step 1 Press and hold set for 5 second...

Page 8: ...changed in the Second Level of programming as well as their options and ranges Parameter Display Symbol Description Range Options Delfield Settings Display Status dSPL Information shown on the displa...

Page 9: ...ost duration time back up for defrost termination temperature Range from 0 min to 4 hours 45 Fan Delay FAnd Delay time for the fan after defrost back up for fan cut in temperature Range from 0 to 59 m...

Page 10: ...Press SET again Press Up or DOWN until the correct time appears on the display Press SET to accept the new time Press DOWN twice to exit the programming mode Example 2 To set one defrost a day at 11...

Page 11: ...reset the display For Codes 3 and 4 press the UP or DOWN button on the display to reset the error message If the display still shows the message the sensor must be replaced The Error Codes 6 and 7 wi...

Page 12: ...Air Curtain Refrigerator Service and Installation Manual For customer service call 800 733 8829 or 800 733 8948 Fax 989 773 3210 www delfield com 12 ACR 26S Wiring Diagram...

Page 13: ...0003 Pan Drip Coil ACR 26S 2194577 Probe ERC2 Control 2190154 Switch Rocker 20A 125V 3516084 Valve Exp 1 2Ton R 404A 000 187 0040 Door Assembly ACR 26S RT 1701147 Gasket Dr 45 50x23 81 000 BJ4 0030 Hi...

Page 14: ...Air Curtain Refrigerator Service and Installation Manual For customer service call 800 733 8829 or 800 733 8948 Fax 989 773 3210 www delfield com 14 Notes...

Page 15: ...Air Curtain Refrigerator Service and Installation Manual 15 For customer service call 800 733 8829 or 800 733 8948 Fax 989 773 3210 www delfield com Notes...

Page 16: ...2 13 9291461 Delfield Thank you for choosing Delfield Help is a phone call away Help our team of professional courteous customer service reps by having your model number and serial number available at...

Reviews: